5. Use & Care of Housing:

5.1 Pre Dive Function Check.

Just before entering the water, make a habit of reviewing that you have carried out the proper steps to close the housing. and the pressure release plug screwed home. Make a visual check of the O-ring seal. It is also useful to switch on the camera, and check that controls e.g. on/off, zoom, shutter functions operate normally. In case of misalignm ent of the camera, simply open the case and correct the problem.

Check housing is closed.

Close pressure release plug

Check battery is full

Check sync cord is connected to the camera housing

Shot the camera at Auto mode

If there is a large change of temperature and the housing is not opened for maintenance between dives, it is recommended to equalize the possible pressure difference between the inside of the housing and the ambient by opening the pressure release plug and close it firmly subsequently.

Always avoid submerging the housing in hot water for a prolonged time or a cleansing tank where the water may be heated up by the sun.

5.2 General Operation.

The control levers and push buttons consist of internal double O-ring seals on a stainless steel shaft. This arrangement is very reliable, however as a precaution, when operating the controls, avoid excessively rapid movements, as this may distort the O-ring. Also please allow for the fact that the camera takes a few seconds to power on. If the camera dose not appear to respond to a control action, make sure that no other controls are pressing on the camera, i.e. locking out further actions. Wear the wrist strap; it is easy to inadvertently let go of the housing, especially if you are distracted.

5.3 Cleaning & Storage.

The body & lid of the housing are made of polycarbonate. Polycarbonate was selected for its outstanding strength stiffness, hardness and toughness. As well as its crystal clear transparency and high gloss surface. It has good resistance to weathering, although long- term exposure to sunlight should be avoided. Normal operating temperature range is 3°C to 36°C (Storage temperature: -10°C to 50°C)

8

8/6/2006

Image 8
Contents Service WarrantySpecifications FL-50 Pressure release plug Set up Instructions Air LockFunction Controls FL-50 Opening levers Special note on responsibility for watertight integrityMaintaining the O-ring Seal When to maintain the O-ring sealProcedure Mounting the flashlight in the housing Stretch the O-ringHousing is now ready for the dive Use & Care of Housing Pre Dive Function Check Cleaning & StorageAccidents Please keep this document for future reference Copy to be returned to 10 Bar Underwater Housings