that no contamination such as dus t, hair, salt, etc. has fallen onto the O-ring or O-ring recess, as a precaution we recommend maintaining the O-ring every time the lid is opened.
Procedure:
∙Place the lid on a firm non-slip level surface.
∙The O-ring can be extracted using an O-ring extractor tool (make sure the tool has no sharp edges). Alternatively use the flats of the thumbs to gently stretch the O-ring on two faces (as shown) thus making a small loop protruding a few mm. The loop can then be grasped between finger and thumb, to pull the O-ring over the lip.
∙Clean the O-ring recess (the square groove where the O-ring sits) with a cotton bud.
∙Inspect the O-ring all the way round its surface for damage such as cuts tears or contamination. This should be done visually and also by feeling the surface texture between finger and thumb.
∙IF THE O-RING IS DAMAGED OR SUSPECTED OF BEING DAMAGED, DISCARD IT IMMEDIATELY. A spare O-ring is supplied with your housing, or a replacement O-ring can be obtained from 10 BAR. If the O-ring is contaminated or suspected of being contaminated, clean it with a cotton cloth that is free of all chemicals or contamination. After cleaning inspect the O-ring again.
∙Once the O-ring has been inspected and verified fit for use, apply a SMALL amount of silicone grease to the O-ring. The silicone grease must be evenly distributed round the O-ring
∙Replace the O-ring into the groove, run a finger round the O-ring, to make sure it is snugly seated in the groove.
3.6Mounting the camera in the housing: Remove the lens cap and wrist strap. Make sure the camera lens to body orientation is in the LCD at top view extended position. The pressure release plug is pulled out before inserting the camera. Attach the plastic slide plate to the camera’s tripod mounting fixture with a coin, screw driver or the end of the universal tool supplied. Take care not to excessively tighten the screw. Slide the camera
into the body along the guide rail inside the bezel. Make sure the camera body reach the limit and test the function of the on/of button on the body of the housing. Note: If you find that control levers do not locate properly with the buttons, please check again that the camera is properly seated to the limit of the guide rail.