CLOSING OF THE HOUSING

Before closing the housing always ensures that:

1.The main O-ring on the front half of the housing is clean, lubricated and properly seated for a positive seal.

2.The sealing surface on the rear half of the housing is clean and free from any scratches or physical damage.

3.All cords or wires are tucked in so that they do not interfere with the closing of the housing.

4.The Function dials Knob on the rear half of housing is pulled out to allow clearance when closing the housing.

To close the housing simply:

I.Join the front and rear halves of the housing using the two dowel pins at the bottom of the housing as a guide.

ii.Hold the housing with both hands and look around the sealing surface to ensure that the O-ring remained properly seated and that no cords, wires or “D-rings” are caught between the edges.

iii.Close the two latches simultaneously. CAUTION: if you feel any resistance as you attempt to close the latches, do not force the closure. Check for an obstruction and try again.

iv.Verify that the safety locking mechanisms of the latches are properly engaged to avoid any accidental opening.

LENS INSTALLATION

With the camera inside the housing, install the lens prepared with the gears through the port opening in the front of the housing. Ensure that the lens mounted gears are properly installed and aligned. Rotate the focus control knobs to ensure that the gears are properly meshed, do not grind and that their rotation is smooth.

Note: to avoid breaking the auto-focus mechanism of the camera you should set the Focus Control to “M” Manual before testing the proper meshing of the gears.

CHANGING A LENS (REMOVING A LENS)

The lens mounted gears may restrict the view and ease of access to the lens release button of camera. A stick or a pencil can be used to push the lens release button on the camera body

MOUNTING THE PORT

Before mounting the Port on the Housing always ensures that;

-The port O-ring is clean, lubricated and properly seated in its groove.

-The sealing surface on the Housing is clean and free of physical damage.

Page10

Image 11
Contents Aquatica A30D Aquatica A30D Housing Safety Precautions Page3 Features Controls in Detail Page6 Preparation of the Ports Preparation of the HousingPreparation of the Lens Focus Gear installationCamera Preparation and Installation Mounting the Port Closing of the HousingLens Installation Changing a Lens Removing a LensTaking a Picture Mounting and Attaching FlashesUsing the Housing Focus ModeHousing Care and MaintenanceTo Service O-RINGS Warranty