Installing the Port There are two port locks on the front of the housing. (See housing front) Each port lock has a Release Button, lift the release button and slide each Port Lock away from the port opening. In the unlocked position the Release Button will remain in the up position as shown.
Port Lock
Release
Button
Locked Position
Lift Release
Button to
Unlock
Pull Back to
Unlocked PositionDisengage Port
Installing the Port cont.
Port Seal Inside View
If the port is installed before the camera is inserted into the housing, look on the inside of the
housings at the port seal. Check
to see that the o’ring is properly sealed as shown in figure 1 and not extruded as shown in figure 2.
To Remove Port
To remove the port lift up on each
To prepare the port for installation, remove the port o’ring and lightly lubricate it. The port seal is a
Check around the perimeter of the port seal to see that the o’ring is properly sealed and not extruded.
13
Using External Strobes Cont.
Using the Conversion Circuitry (Set DS Substrobe to TTL mode)
• Mode and Compensation Buttons
The Conversion Circuitry default is set to TTL. To switch between TTL and Manual Modes depress both Mode Buttons at the same time and keep them depressed until you see the desired Yellow LED Mode illuminate.
• TTL Mode (indicated when the Yellow LED directly below TTL is illuminated). TTL Mode is the default setting. When the DS Substrobe is powered ON the Yellow TTL LED will illuminate. None of the Red LEDs will illuminate. This indicates that NO (+) plus or
• Manual Mode (indicated when the Yellow LED directly below the M is illuminated). When the Manual Mode is selected the Red LED directly below the F (full power) will illuminate. Note that the Manual minus
15
Release Button and slide the port lock away from the port.
Caution:
After installing the port, turn the Zoom Control knob on the housing. If the Zoom Control is difficult to turn, the gear sleeve may be warped. If so reduce or omit any rubber installed on the Zoom Clamp. (Fig.H on pg.10). If the Zoom Clamp is still warped, use of the #5509.28 package may be required.(See page 7)
14
NOTE: DS Substrobe
• DS50 SubStrobes with a Serial Number below 63,850 can not be updated to operate with the TTL Conversion Circuitry.
• DS50 SubStrobes with a Serial Number between 63,850 and 69,999 operate with the TTL Conversion Circuitry, but require update to provide optimum performance.
• DS50 Substrobe with a Serial Number of 70,000 or higher or with one of the two following labels in the battery compartment provide optimum performance with the TTL Conversion Circuitry. DS125 Substrobes
• DS125 Substrobes with a Serial Number below 2,500 must be updated to operate correctly with the TTL Conversion Circuitry.
• DS125 Substrobes with a Serial Number between 2,501 and 4,900 operate with the TTL Conversion Circuitry but require update to provide optimum performance.
• DS125 Substrobe with a Serial Number of 5,000 or higher or with one of the two following labels in the battery compartment provide optimum performance with the TTL Conversion Circuitry.
For Substrobe Up-Date:
Contact Ikelite for information.
ikelite
Substrobe
| serial number | serial number |
|
|
16