Ikelite 400D instruction manual Control Maintenance, Flat Port with Focus

Page 6

Ports Continued

FLAT PORT

For standard,macro, and telephoto lenses.

Due to refraction flat ports reduce the angle-of -coverage of a lens and at the same time enlarge the image. This makes the flat port ideal when using standard, macro or zoom lenses to shoot small subjects. Note that if a port is long enough to accommodate the full length of a 1:1 macro lens, the lens may vignette when used at infinity. If access to the lens' full range is desired, then select a dome port instead.

FLAT PORT

#5501 . . . . . Lens up to 6.3cm (2.5") #5502 . . . . . Lens 6.3-8.9cm (2.5-3.5") #5502.41 . . Lens 7.9-10.4cm (3.14- .125") #5505 . . . . . Lens 8.9-11.4cm (3.5-4.5") #5505.45 . . Lens 10.4-13cm (4.1-5.125") #5505.5 . . . Lens 11.4-14cm (4.5-.5") #5505.58 . . Lens 13-15.5cm (5.1-6.125")

FLAT PORT WITH FOCUS

For long lenses whose focus collar extends beyond the housing focus. Telephoto lenses longer than 135mm arenot recommended. #5506 . . . Lens 8.9-11.4cm (3.5-4.5")

#5506.5 . Lens 11.4-14cm (4.5-5.5")

5507 . . . . Lens 14-16.5cm (5.5-6.5")

5508 . . . . Lens 16.5-19cm (6.57- .5")

5508.05 . Nikor 105mm lens only

21

Maintenance

The Ikelite Housing should be given the same care and attention as your other photographic equipment. In addition to normal maintenance we recommend that the housing be returned to Ikelite periodically to be checked and pressure tested.

1. Do Not leave the camera and housing in direct sunlight for prolonged periods. Heat may damage the camera.

2. Do Not ship the camera in the housing.

3. Before using the housing, always check the tightness of the set screw in each control knob.

Check each control gland penetrating the housing to make sure they are tight. There is a slight chance that either could vibrate loose during travel.

4. Keep the back and port o’ring clean and lightly lubricated. To lubricate remove the o’ring from the back. Put a small amount of lkelite lubricant on your fingers. Draw the o’ring through your fingers to apply a light coating of lubricant. Only apply enough lubricant to make the o’ring feel slick. Do Not stretch the o’ring. This light coating of lubricant will help to keep the o’ring from drying out and will help to show a dark sealing line when the housing back is properly sealed.

5. Keep the area where the o’ring fits and the sealing surface clean.

6. Rinse the housing exterior thoroughly in fresh water after each salt water use. Depress push buttons several times during rinse. Dry with a soft cloth. Dry port to eliminate water spotting.

After several uses in salt water soak the housing in a mild soap solution, rinse and dry.

CAUTION: Never use spray lubricants as the propellant ingredient can cause the plastic housing to crack.

23

Lens & Port Recommendations

Flat Port

Flat Port w/Focus

Canon Lenses

Dome

14mmEF1:2.8

5503(1)

 

 

15mmFisheye

5503.15

 

 

20mm

5503

 

 

24mm

5503

5501

 

28mm

5503

 

35mm

5503

5501

 

50mmMacro1:2.8

5503.50

5505

 

100mmMacro

NR

5505.5

 

100mmEFMacro1:2.8

NR

5505.58(4)

5508.45

100mmUSMMacro1:2.8

NR

5505.45

16-35mmUSM

5503.55(2)

 

 

17-35Ultrasonic

5503.50(2)

 

17-40mmUSM

5503.50(2)

 

 

18-55EF-S

5503

 

 

*20-35mm

5503.50

 

 

*20-35Ultrasonic

5503(2)

 

 

*22-55Ultrasonic

5503.50(2)

 

 

*24-85mm

5503.50

 

 

*28-70mm

5503.85(3)

 

*28-80mm

5503.50

 

 

*28-80mmUSM

5503.50(2)

 

 

28-105mmEFUSMII

5503.55(2)

 

 

*28-105mmUSM

5503.80(2)

5502

 

*35-80mm

5503

 

*35-135mm

5503.80

Flat Port

 

Sigma AF (Canon)

Dome

 

*28-105mmf/2.8-4

5503.80(2)

 

 

(*)Zoomlensesthatdonotfocusto12”requirea+4diopterclose-uplens beaddedtothelenswhenusedunderwaterbehindadomeport.

(1)Portshademayhavetoberemovedtoavoidvignetting.

(2)Lensrequiresspecialzoomclampsandfocussleeve#5509.28.

(3)Lensdiameterdoesnotallowzoomoperationinthehousing.

(4)AutoorManualfocusmustbeselectedbeforeclosingthehousing. Requiresspecialzoomclampandfocussleeve#5509.28formanualfocus.

22

Control Maintenance

Ikelite controls are designed to provide years of reliable service with minimal maintenance.

1. Push button controls require no maintenance other than rinsing in fresh water after saltwater use. If a push button control becomes difficult to push or if it sticks when depressed, soak the housing in luke warm fresh water. After a few minutes operate the push button. If this does not correct the problem, return the housing to Ikelite for maintenance.

2. Some of the controls have long shafts. These controls can be

lubricate shaft

housing

pull out to expose shaft

pulled out, exposing the shaft (see drawing).

To lubricate the control, gently pull on the knob until the stainless steel shaft is exposed. Lightly lubricate the shaft, then move the shaft in and out several times. This will lubricate the x’ring in the Ikelite control gland. This should be done before using the housing after a prolonged storage period, or once a week when the housing is in use.

24

Image 6
Contents ID switch to DS51 Opening the Housing Lid Snaps have a LockLCD Auto Off to the Disable Mode Inst Ructi Ma nualZoom Clamps & Gear Sleeves Included with Housing Closing the HousingPreparing to Install Zoom Clamp & Gear Sleeve Flash Connection for External StrobesInstall the Gear Sleeve Installing the Zoom ClampInstalling the Gear Sleeve Installing the Port Using External StrobesStrobe Arms Flat Port MaintenanceControl Maintenance Flat Port with FocusGeneral Tips Ikelite Limited WarrantyReturning Products for Service Photo Tips