IDEAL INDUSTRIES HeatSeeker 160 Focusing, Saving an image, Temperature measurement

Page 6

#61-846

3.4Focusing

Gently rotate the lens clockwise and counter-clockwise to focus the image.

Remember to remove the lens cap.

Focus Bar

Out of Focus

Focused

When focusing a focus bar appears on the screen to assist in focusing the image. It indicates the approximate distance in feet (in meters when °C is selected) of a focused target from the camera.

3.5. Saving an image

Save image button

To save a live or frozen image, press the Save button once. If Caption Mode or Voice Annotation has been turned on, a text caption or voice annotation can be attached to the image (see section 6).

3.6. Temperature measurement

One of the key functions of a thermal imager is obtaining temperature information about the scene. The IDEAL 61-846 has a variety of measurement options to provide maximum flexibility.

The display of temperature values and related items depends on the combination of the measurement and display options selected. Temperature readings are displayed at the top of the display. In the default mode, a single reading in C indicates the temperature at the center point of the cursor. The other reading at the top of the display is the reflected temperature setting(see section 5.1.). The temperature range within the scene is indicated by a scale on the right hand side of the display.

ND-7521-1

Page 6 of 25

Image 6
Contents HeatSeeker Dual View Thermal Imaging Camera Contents Contents of the Case Function Keys Main Controls BackFront Function Key ND-7521-1Getting started Switching the camera on/off Charging the batteryChanging the battery Saving an image FocusingTemperature measurement Focus Bar Out of Focus FocusedFunction buttons Moving the cursorImage alignment Examples of alignmentTurning the visible image off and on Thermal and visible image blendingImage freeze Manual controlLight MenuMenu structure Infrared settings Tabular temperature values Tagged temperature values Measurement optionsRed isotherm Blue isotherm Combined isotherms Vertical Profile Horizontal profileCamera settings Audio settings Date & Time settings Image browserDisplay Settings Language selectionVoice message PlaybackText captions Appendix A1. Emissivity TablesFunction Key two A2. Full Icon ListFunction Key one Function Key threeA3. Technical specification Computer Requirements for PC software Ideal 61-846 Includes Optional AccessoriesInterfaces EnvironmentWarranty Statement Specifications are Subject to Change Without Notice