GE1900 User Manual |
Sync Out 2 and Sync Out 3
These signals only function as outputs and can be configured as follows:
Exposing | Corresponds to when camera is |
| integrating light. |
Trigger Ready | Indicates when the camera will accept a |
| trigger signal. |
Trigger Input | A relay of the trigger input signal used |
| to “daisy chain” the trigger signal for |
| multiple cameras. |
Readout | Valid when camera is reading out data. |
Strobe | Programmable pulse based on one of the |
| above events. |
Imaging | Valid when camera is exposing or |
| reading out. |
GPO | User programmable binary output. |
Any of the above signals can be set for active high or active low.
These signals are
ISOLATED GROUND
These signals are internally connected to isolated ground. At least one of these signals must be connected to the users external circuit ground. However, it is good practice to provide a dedicated ground return for each signal used. For example, a good cable design would connect the required signal on one conductor of a twisted pair and the isolated ground on the second conductor of the same twisted pair.
DNC
These signals are reserved for future use and should be left disconnected.
Item 3: Mini-SMB Trigger Input
The
The
Prosilica Inc. | 7 |