TANDBERG 1080p manual Camera commands, Command Command Packet Comments

Page 15

PrecisionHD 1080p Camera

What’s in this user guide?Getting startedConnecting the camera

Camera commands

Command

Command Packet

Comments

 

 

 

 

Power_On

8x

01 04 00 02 ff

Power control. This command

 

 

 

stores the zoom and focus

Power_Off

8x

01 04 00 03 ff

value and reset these motors.

 

 

 

 

 

 

Used for Tiger if the camera

 

 

 

was on for a long time.

 

 

 

 

Video_Format

8x

01 35 0p 0q 0r ff

Selects video format. p =

 

 

 

reserved. q = video mode. r =

 

 

 

See the chapter about the DIP

 

 

 

switch settings

 

 

 

 

WB_Auto

8x

01 04 35 00 FF

WB: White Balance

 

 

 

 

WB_Table_Manual

8x

01 04 35 06 ff

 

 

 

 

 

WB_Table_Direct

8x

01 04 75 0p 0q 0r 0s ff

Used if WBmode = Table

 

 

 

manual pqrs = wb table.

 

 

 

 

AE_Auto

8x

01 04 39 00 FF

AE: Automatic Exposure.

 

 

 

 

AE_Manual

8x

01 04 39 03 FF

 

 

 

 

 

Iris_Direct

8x

01 04 4B 0p 0q 0r 0s FF

Used if AE mode = Manual.

 

 

 

pqrs: Iris position, range 0..50

 

 

 

 

Gain_Direct

8x

01 04 4c 0p 0q 0r 0s FF

Used if AE mode = Manual.

 

 

 

pqrs: Gain position, values:12-

 

 

 

21dB.

 

 

 

 

Backlight_On

8x

01 04 33 02 FF

BacklightCompensation mode

 

 

 

 

Backlight_Off

8x

01 04 33 03 FF

 

 

 

 

 

Mirror_On

8x

01 04 61 02 ff

Sony calls this CAM_LR_

 

 

 

Reverse. RR (FT/AT mirror

Mirror_Off

8x

01 04 61 03 ff

command)

 

 

 

 

 

 

 

Flip_On

8x

01 04 66 02 ff

Sony calls this CAM_ImgFlip.

 

 

 

 

Flip_Off

8x

01 04 66 03 ff

 

 

 

 

 

Gamma_Auto

8x

01 04 51 02 ff

Gamma mode. Default uses

 

 

 

gamma table 4.

Gamma_Manual

8x

01 04 51 03 ff

 

 

 

 

 

Gamma_Direct

8x

01 04 52 0p 0q 0r 0s ff

pqrs: Gamma table to use in

 

 

 

manual mode. Range 0-7.

 

 

 

 

MM_Detect_On

8x

01 50 30 01 ff

Turn on the Motor Moved

 

 

 

Detection (camera recalibrates

 

 

 

if touched)

 

 

 

 

MM_Detect_Off

8x

01 50 30 00 ff

Turn off the Motor Moved

 

 

 

Detection (camera does not

 

 

 

recalibrate if touched)

 

 

 

 

User Guide

Making your own cables

 

Remote control

Contact information

 

 

 

 

Command

Command Packet

Comments

 

 

 

 

Call_LED_On

8x

01 33 01 01 ff

Refers to orange LED on top

 

 

 

of camera. Will always be off

Call_LED_Off

8x

01 33 01 00 ff

at startup.

 

 

 

Call_LED_Blink

8x

01 33 01 02 ff

 

 

 

 

 

Power_LED_On

8x

01 33 02 01 ff

Green power LED. If switched

 

 

 

to off and stored to startup

Power_LED_Off

8x

01 33 02 00 ff

profile, it will always be off.

 

 

 

 

 

 

 

IR_Output_On

8x

01 06 08 02 ff

See IR push message.

 

 

 

 

IR_Output_Off

8x

01 06 08 03 ff

 

 

 

 

 

IR_CameraControl_On

8x

01 06 09 02 ff

Lets up/down/left/right/

 

 

 

zoom+/- on the IR remote

IR_CameraControl_Off

8x

01 06 09 03 ff

control the camera directly.

 

 

 

 

 

 

Those keycodes will be sent to

 

 

 

the controller if IR Output is on.

 

 

 

 

BestView_On

8x

01 50 60 0p 0q ff

Turn BestView on or off.

 

 

 

pq=time (in seconds) Will

BestView_Stop

8x

01 50 60 00 00 ff

generate push message(s) as

 

 

 

 

 

 

specified above when the time

 

 

 

runs out.

 

 

 

 

D14245.04—DECEMBER 2008

15

Image 15
Contents Camera User Guide Tandberg PrecisionHD 1080pWhat’s in this user guide? Chapter Getting startedCascaded cameras Camera at a glanceHdmi and HD-SDI Cable lengthsBest view face recognition Using Best ViewConnecting the camera Hdmi cable Connecting the cameraDIP switch settings for video output formats Video output formatsLine voltage frequency Cameras in daisy chain Making your own cables Making your own cables Controlling cameras from remote Visca messages Interfacing to the camera using the Visca protocolPush messages Network and interface commandsCommand Command Packet Comments Camera commandsPtzf movement commands Inquiries Command Command Packet ResponseSoftware upload commands Debug commandsOther commands Video mode selection DIP SwitchMethod Headquarters European Headquarters Tandberg