Ashly TRA-4150 manual Introduction, AC Power Requirements, Unpacking

Page 4

Operating Manual - Powerflex Multi-Channel Power Amplifier

1.INTRODUCTION

The Ashly Powerflex amplifiers combine the effi- ciency of a MOSFET high-speed switching output stages with the sophistication of modern microprocessors and DSP technology to produce a multi-channel amplifier with un- precedented versatility and power in a single 3RU pack- age.

Although similar to other amplifiers with class D output stages, Powerflex amplifiers employ internal mi- croprocessor and DSP algorithms to optimize output switching characteristics and eliminate the usual harshness associated with high-frequency audio in standard class D amplifiers. This optimization results in a spread-spectrum switched output that varies with input amplitude and fre- quency, and minimizes radiated emissions by eliminating the single-frequency high-energy radiated interference normally associated with switching outputs. The use of a simple linear power supply removes another potential source of radio-frequency interference, an important con- sideration as racks become more and more heavily popu- lated with digital signal processing equipment. A small switching supply using flyback topology provides an effi- cient power source for logic, protection, pre-amplifier and indicator circuits.

The right to any claim against a public carrier can be forfeited if the carrier is not notified promptly and if the shipping carton and packing materials are not avail- able for inspection by the carrier. Save all packing mate- rials until the claim has been settled.

3.AC POWER REQUIREMENTS

3.1Voltage Requirements

The Powerflex amplifiers can be operated from nominal 120VAC or 240VAC, 50/60Hz mains. This is user- configurable by changing the insert in the AC Inlet (See section 7.9). The power connector on the amplifier accepts a standard IEC-320 receptacle.

For nominal 120VAC operation, the power cord should be three-conductor, rated for at least 13A (16AWG). The line fuse should be type MDA, 12A.

For nominal 240VAC operation, the power cord should be three-conductor, rated for at least 10A (18AWG). The line fuse should be type MDA, 10A.

3.2Current Requirements

To assure reliable operation, the usual protection from excessive high-frequency, DC offset, and thermal overload is supplemented by power supply undervoltage, power supply overvoltage, and output overcurrent detec- tion, all monitored and controlled by the latest in minia- turized microprocessor technology.

In sum, Ashly Powerflex amplifiers combine the best of the new digital technologies with the best of the traditional analog technologies to provide a product that will supply clean sound at full output from every channel while generating minimal heat, thus increasing the reli- ability of every other piece of equipment in a rack as well as preserving its own.

1.) Idle (no audio):

Powerflex 6250

120V: 0.81A

240V: 0.42A

2.) With typical audio inputs:

8loads on all channels 120V: 4A

240V: 2A

4loads on all channels 120V: 6.5A

240V: 3.3A

Powerflex 4400

120V: 0.9A

240V: 0.5A

120V: 4.6A

240V: 2.3A

120V: 7.0A

240V: 3.5A

2.UNPACKING

As a part of our system of quality control, every Ashly product is carefully inspected before leaving the factory to ensure flawless appearance. After unpacking, please inspect for any physical damage. Save the ship- ping carton and all packing materials, as they were care- fully designed to reduce to minimum the possibility of transportation damage should the unit again require pack- ing and shipping. In the event that damage has occurred, immediately notify your dealer so that a written claim to cover the damages can be initiated.

70 Volt systems - (Powerflex 6250 Only,

3 channels Bridged Mono) 120V: 6.5A

240V: 3.3A

Powerflex amplifiers consumes less than 12 amps when all channels operate at 1/8 power into rated (4 ohm) loads. This condition satisfies the UL, CSA and building electrical code requirements for a piece of audio equip- ment not to consume more than 80% of the current avail- able when plugged into a grounded 15 amp outlet and operated at 1/8 of maximum power.

4

Image 4
Contents Powerflex  Table Of Contents Design Theory Introduction AC Power RequirementsUnpacking Cable Requirements RACK-MOUNTING RequirementsFront Panel Indicators Rear Panel Features Input ConnectorsInput Ground Switch 50Hz Low Cut SwitchStereo/Mono Switch Multi-Channel OperationPowerflex AC InletSELF-PROTECTION Features Specific conditions resulting in a fault are as followsSix Channel Setup dual stereo Typical ApplicationsBridged Mono Setup Design Theory Troubleshooting TipsNo Audio Output Powerflex Dimensions 11.2 Distorted Sound 11.3 Hum or Buzz NoiseSpecifications Warranty Information6250-3

TRA-4150 specifications

The Ashly TRA-4150 is a robust, high-performance amplifier designed to meet the demanding requirements of modern audio installations. Known for its reliability and exceptional sound quality, the TRA-4150 is ideal for both commercial and residential applications, including venues such as auditoriums, houses of worship, and entertainment spaces.

One of the defining features of the TRA-4150 is its power output. With a maximum output of 150 watts per channel at 4 ohms and 75 watts per channel at 8 ohms, this amplifier delivers enough power to drive a variety of speakers efficiently. It is equipped with a class AB topology, which ensures low distortion and high sound fidelity, making it suitable for critical listening environments.

The TRA-4150 boasts numerous advanced technologies designed to enhance performance and user experience. It incorporates a comprehensive protection system that includes thermal protection, short circuit protection, and DC fault protection, ensuring safe operation under various conditions. This reliability is crucial in professional settings where equipment failure is not an option.

Furthermore, the Ashly TRA-4150 features integrated signal processing capabilities, allowing users to optimize sound performance with ease. Its variable high-pass and low-pass filters enable tailored control over the audio signal, ensuring that sound output is clear and well-defined across frequencies.

Connectivity is another strong point of the TRA-4150. The amplifier supports both balanced and unbalanced input options, ensuring compatibility with a variety of audio sources and equipment. Additionally, the unit has a convenient input gain control for each channel, allowing for precise adjustment of signal levels.

The design of the TRA-4150 is both sleek and functional. The unit has a compact form factor, making it easy to integrate into existing audio setups. Furthermore, the built-in fan cooling system ensures efficient heat dissipation, which is vital for maintaining performance during extended use.

Overall, the Ashly TRA-4150 amplifier stands out in the market due to its powerful output, advanced protection technologies, and user-friendly features. Whether in a live performance setting or a fixed installation, the TRA-4150 delivers reliability and exceptional audio quality, making it a preferred choice for audio professionals and enthusiasts alike.