PSA GCC-250, GCC-500, GCC-100 manual Quick Start Guide

Page 6

®

Quick Start Guide

Owner’s Reference GCP Stereo Preamplifier

Power down first

Connect the inputs

Balanced inputs

RCA inputs

Speaker Cables

Check for proper polarity

Subwoofer connections

Once you have decided on the location and chosen the appropriate power cables, you are ready to install the GCC Control Amplifi er.

We recommend that you power the entire system down before installing the GCC Control Amplifi er.

Insert the GCC Control Amplifi er into the system.

Connect the inputs of the GCC Control Amplifi er to the output of your source equipment such as CD players, phono preamplifi ers, tuner,

etc. There are two choices of inputs: balanced or single ended. There is one balanced input and four single ended RCA inputs.

Balanced inputs require a source that has a balanced output. These outputs are the preferred method of connection as a balanced XLR type of output allows the lowest noise connection, and allow owners to take advantage of the high common mode rejection characteristics found in the Gain Cell of the GCC

Control Amplifi er. Be sure to use a high quality well shielded and well regarded interconnect for this critical link. PS Audio makes an entire line of excellent choices for interconnects, perfectly matched to your equipment’s needs.

RCA or single ended inputs will be the typical inputs as many sources have only this standard type of input. Be sure to use a high quality well shielded and well regarded interconnect for this critical link.

Speaker cables are a critical link between your loudspeakers and your new GCC Control Amplifi er. Make sure you use only the highest quality such as a PS Audio speaker cable that will be perfectly matched to your equipment’s needs.

Pay close attention to the polarity on the rear panel binding posts. It is critically important that you match plus and minus (red and black) of the GCC Control Amplifi er to the plus and minus of your speaker. Carefully observe the polarity. The plus or red terminal of the GCC Control Amplifi er must eventually be tied to the plus or red terminal of your loudspeaker. The GCC Control Amplifi er is a non- inverting amplifi er design meaning it is in phase with the input signal.

Use the Aux Out RCA connectors on the rear of the GCC Control Amplifi er to feed your subwoofer’s low level inputs. Some subwoofers have high level inputs where the output of the amplifi er can be connected as an input to the subwoofer. Generally there is no problem. In a few rare instances there may be a problem, which will show itself as problematic if the amp’s protection comes on after hooking up the sub. REL subwoofers and some Sunfi re subwoofers can be problematic. Please check with the factory or your dealer if you encounter these subwoofers or any problems.

4826 Sterling Drive, Boulder, CO 80301

Quick Start Guide 2

PH: 720.406.8946 service@psaudio.com www.psaudio.com

 

©2004 PS Audio International Inc. All rights reserved.

Image 6
Contents Owner’s Reference DocumentIntroduction Important Safety Instructions IntroductionTable Of Contents What you can expect Location Isolation Power Cables ConditionersGetting Started Getting StartedQuick Start Guide Quick Start GuidePush the front panel logo to turn it on Setup instructions Setup InstructionsInput Name Editing Setup instructions Software versionOperating Guide Volume control Mute controlUp/Down selector Power Button Balance controlHT Bypass Phase Control Dim Control Questions and Answers Placement?Front panel power button Isolation?What voltages can the amp run on? Troubleshooting TroubleshootingTroubleshooting Problems with subwoofers Specifi cations SpecificationsWarranty WarrantyConditions Remedy Miscellaneous Outside the US Service ServiceIf you have problems Voltage changes Sterling Drive, Boulder, CO Your serial number Your purchase informationYour dealer or distributor’s information Date of purchase

GCC-100, GCC-500, GCC-250 specifications

The PSA GCC series, which includes the GCC-250, GCC-500, and GCC-100 models, represents a pioneering line of gas cold cryogenic systems developed by the renowned manufacturer, PSA. These systems are distinguished by their advanced features, cutting-edge technologies, and unique characteristics that cater to various industrial applications.

The GCC-250 is designed for high efficiency and reliability in producing nitrogen, oxygen, and argon from air. It boasts a compact design, making it suitable for installations where space is at a premium. Its energy-efficient operation is facilitated by the latest in cryogenic technology, allowing for low power consumption while maintaining maximum output. Key features of the GCC-250 include a modular design for easy maintenance, integrated control systems for remote monitoring, and a user-friendly interface that simplifies operation. Additionally, it incorporates safety mechanisms to ensure optimal performance even under varying environmental conditions.

Next in the line is the GCC-500, which offers increased capacity and advanced efficiency compared to its smaller counterpart. With a production capability of up to 500 liters per hour, the GCC-500 is ideal for medium to large-scale industrial applications. This model employs a state-of-the-art dual-column adsorption technology, which enhances the purity of gases produced while minimizing waste. The GCC-500 also incorporates advanced thermal insulation and heat exchange technologies, which further optimize the energy use and operational cost. It features an intuitive control system with predictive maintenance capabilities, allowing for real-time diagnostics and reduced downtime.

At the top end of the series, the GCC-100 is engineered for high-demand applications that require large volumes of gas. With its robust construction and innovative design, this model can produce an impressive output, catering to industries such as aerospace, pharmaceuticals, and food processing. The GCC-100 utilizes a proprietary liquefaction cycle that ensures exceptional gas purity and can handle variations in feed conditions without compromising performance. Like the GCC-500, it is equipped with advanced automation and control systems for seamless operation. Additional features include enhanced safety protocols, comprehensive data logging, and customizable configurations to meet specific client requirements.

Overall, the PSA GCC series embodies the latest advancements in cryogenic gas production technology, offering efficient, reliable, and safe solutions for diverse industrial needs. With their unique features and robust performance, these units are well-suited for businesses aiming to enhance productivity while minimizing operational costs.