Canon 450D user manual Set up Instructions Air Lock, Pressure release plug, Opening levers

Page 3

4.Set up Instructions

4.1 Air Lock:

The body and lid are designed with the Air Lock system no clipclosure arrangement. Testing has shown that this arrangement allow the water to exert an even pressure on the O-ring, increasing the reliability of the watertight seal.

4.2 Pressure release plug

To open the housing, the pressure release plug must be first unscrewed and then pulled out all the way (Counter-clockwise) (Fig 1). This provides a passage for the air to pass though and eliminate the pressure different between the inside of the housing and the ambient. The plug onsists of an internal double O-ring seal on the stainless steel slide shaft.

These internal O-rings form the watertight seal. There is also a large outer O-ring under the knob. This O-ring serves to prevent contamination of the slide shaft, with dirt, salt etc., and is not required for watertight integrity. If this O-ring should become detached, it can simply be pushed back in place.

4.3 Opening levers

After unscrewing and pulling out the pressure release plug, the lid can be opened. To overcome the friction of opening, use lever (Fig. 2) to push against the lid with a cam action. Be sure they are inserted all the way flat to the housing before turning to avoid damaging the protrusions on the lid. The body has four holes on each corner edges for opening. Gently lever off the lid with the supplied opening lever (Fig. 3) taking care not to twist the lid excessively. The lid should be opened keeping it approximately paralleled to the body at all times, turn first one corner a little, then the other a little, and repeat again until the lid is opened. Remember to unscrew and pull out the pressure release plug all the way first, otherwise the air pressure will resist attempts at opening. Lay the lid on a flat stable surface after opening.

3

Image 3
Contents Camera Housing Model 450D Canon Function Controls 450D Specifications 450DSet up Instructions Air Lock Pressure release plugOpening levers Special note on responsibility for watertight integrity When to maintain the O-ring sealProcedure Mounting the flashlight in the housing Cleaning & Storage Use & Care of Housing Pre Dive Function CheckAccidents TransportationPlease keep this document for future reference