Adcom GFA7807 owner manual Outdoor Antenna Grounding

Page 4

THE FOLLOWING PRECAUTIONS AND SAFETY INSTRUCTIONS ARE REQUIREMENTS OF UL AND CSA SAFETY REGULATIONS

Warning: To reduce the risk of fire or electric shock, do not expose this unit to rain or moisture.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

The graphic symbol of a lightning flash with an arrow point within a triangle signifies that there is dangerous voltage within the unit and it poses a hazard to anyone removing the cover to gain access to the interior of the unit. OnIy qualified service personnel should make any such attempt.

The graphic symbol of an exclamation point within an equilateral triangle warns a user of the device that it is necessary to refer to the instruction manual and its warnings for proper operation of the unit.

Do not place this unit on an unstable cart, stand, tripod, bracket, or table. The unit may fall, causing serious injury to a child or adult, and serious damage to the unit. Use only with a cart, stand, tripod, bracket, or table recommended by the manufacturer or sold with the unit. Any mounting of the device should follow the manufacturer’s instructions, and should use a mounting accessory recommended by the manufacturer.

Read all the safety and operating instructions before connecting or using this unit.

Retain this notice and the owner’s manual for future reference.

All warnings on the unit and in its operating instructions should be adhered to.

All operating and use instructions should be followed.

Do not use this unit near water. For example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool.

ATTENTION

POUR PREVENIR LES CHOCS ELECTRIQUES NE PAS UTILISER CETTE FICHE POLARISEE AVEC UN PROLONGATEUR, UNE PRISE CE COURANT OU UNE AUTRE SORTIE CE COURANT, SAUF SI LES LAMES PEUVENT ETRE INSEREES A FOND SANS EN LAISSER AUCUNE PARTIE A DECOUVERT.

CAUTION

TO PREVENT ELECTRIC SHOCK DO NOT USE THIS POLARIZED PLUG WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.

CAUTION POWER LINES

Any outdoor antenna must be located away from all power lines.

OUTDOOR ANTENNA GROUNDING

If an outside antenna is connected to your tuner or tuner/preamplifier, be sure the antenna system is grounded so as to provide some protection against voltage surges and built-up static charges. Section 810 of the National Electrical Code, ANSI/NFPA No. 701984, provides information with respect to proper grounding of the mast and supporting structure, grounding of the lead-in wire to an antenna discharge unit, size of grounding conductors, location of antenna discharge unit, connection to grounding electrodes, and requirements for the grounding electrode.

a. Use No.10 AWG (5.3 mm2) copper, No.8 AWG (8.4 mm2) aluminum, No.17 AWG (1.0 mm2) copper clad steel or bronze wire, or larger, as a ground wire.

b. Secure antenna lead-in and ground wires to house with stand-off insulators spaced from 46 feet (1.221.83 m) apart.

c. Mount antenna discharge unit as close as possible to where lead-in enters house.

d. Use jumper wire not smaller than No.6 AWG (13.3 mm2) copper, or the equivalent, when a separate antenna grounding electrode is used. See NEC Section 810-21 (j).

EXAMPLE OF ANTENNA GROUNDING AS PER NATIONAL ELECTRICAL CODE INSTRUCTIONS CONTAINED IN ARTICLE 810. RADIO AND TELEVISION EQUIPMENT.

The unit should be installed so that its location or position does not interfere with its proper ventilation. For example, it should not be situated on a bed, sofa, rug, or similar surface that may block the ventilation openings; or placed in a built-in installation, such as bookcase or cabinet, that may impede the flow of air through its ventilation openings.

The unit should be situated away from heat sources such as radiators, heat registers, stoves, or other devices (including amplifiers) that produce heat.

The unit should be connected to a power supply outlet only of the voltage and frequency marked on its rear panel.

The power supply cord should be routed so that it is not likely to be walked on or pinched, especially near the plug, convenience receptacles, or where the cord exits from the unit.

Clean unit only as recommended in its instruction manual.

The power supply cord of the unit should be unplugged from the wall outlet when it is to be unused for a long period of time.

Care should be taken so that objects do not fall, and liquids are not spilled, into the enclosure through any openings.

This unit should be serviced by qualified service personnel when: A. The power cord or the plug has been damaged; or

B. Objects have fallen, or liquid has been spilled, into the unit; or C. The unit has been exposed to rain, or liquids of any kind; or

power lines

ground clamp

service entrance conductors

service entrance equipment

ground wire, a,b ground clamps

power service grounding electrode system

(e.g. interior metal water pipe)

bonding jumper, d

standoff insulators, b

mast

antenna lead-in wire

antenna discharge unit, c

to external antenna terminals of radio receiver

ground wire, a,b ground clamps

optional antenna grounding electrode driven 8 feet (2.44 M) into the earth if required by local codes.

D. The unit does not appear to operate normally, or exhibits a marked change in performance; or

E. The device has been dropped, or the enclosure damaged.

DO NOT ATTEMPT SERVICING OF THIS UNIT YOURSELF.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

NOTE TO CATV SYSTEM INSTALLER

This reminder is provided to call the CATV system installer’s attention to Article 82022 of the National Electrical Code that provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as practical.

Image 4
Contents GFA-7805 & GFA-7807 Welcome Table of Contents Outdoor Antenna Grounding GFA-7805 Features Adcom Protection Plan USA OnlyIntroduction Installing the GFA-7805/7807Unpacking the GFA-7805/7807 GFA-7807 Rear Panel GFA-7807 Front Panel AC Power Cord On/Off SwitchPower LED InputsThermal Protection LEDs Distortion Alert LEDsLeft Back Left Surround Connecting the GFA-7805/7807 to Your Speakers Symptom Possible Reason Possible Solution Caring for Your GFA-7805/7807 ServicingGFA-7805 Specifications GeneralGFA-7807 Specifications Adcom

GFA7807 specifications

The Adcom GFA-7807 is a high-performance power amplifier known for its exceptional sound quality and engineering. As part of Adcom's renowned lineup of audio equipment, the GFA-7807 is celebrated for its ability to deliver powerful and accurate audio reproduction, appealing to audiophiles and casual listeners alike.

One of the standout features of the GFA-7807 is its impressive power output. It provides 200 watts per channel at 8 ohms and can deliver up to 350 watts per channel at 4 ohms. This robust power handling allows it to drive even the most demanding speakers with ease, ensuring that the music remains dynamic and detailed, regardless of the volume level. This amplifier's ability to maintain its performance under high loads is a crucial attribute for high-end audio setups.

The GFA-7807 employs a Class AB amplification design, which balances the benefits of both Class A and Class B amplifiers. This design helps minimize distortion and crossover issues, ensuring that the output remains clean and precise, particularly in the midrange frequencies. The amplifier's low total harmonic distortion (THD) rating further enhances its audio fidelity, making it an excellent choice for critical listening.

In terms of build quality, the Adcom GFA-7807 is constructed with rugged components designed to withstand the rigors of prolonged use. The sturdy chassis and high-quality connectors contribute to its durability, while also minimizing interference and maintaining signal integrity. The amplifier is also equipped with extensive protection circuits, which guard against short circuits, thermal overload, and other potential damage conditions.

Another noteworthy characteristic of the GFA-7807 is its versatility. It features multiple input options, including balanced XLR and unbalanced RCA connectors, allowing for seamless integration into various audio systems. Additionally, its rack-mountable design makes it an ideal choice for professional setups and home theaters alike.

Overall, the Adcom GFA-7807 power amplifier stands out in the audio landscape due to its impressive power handling, low distortion, rugged construction, and versatility. Whether used in a high-fidelity music system or a home theater, it delivers a remarkable listening experience that captures the essence of the original recording, making it a must-consider option for enthusiasts looking to elevate their audio setups.