EverFocus EZ180 user manual Iris Level Adjustment, Iris ALC Adjustment

Page 10

Settings

The camera is set up at factory and normally requires no adjustments. Sometimes, however, adjustments may be necessary. Please refer to the following description for the function details.

„The IRIS ALC and IRIS Level adjustments are located on the side circuit board, use a screwdriver to adjust if it’s necessary.

IRIS Level

IRIS ALC

Adjustment

Adjustment

Control Switches

IRIS Level Adjustment

To adjust brightness level –

zTurn the IRIS Level Adjustment VR counterclockwise to get darker picture.

zTurn the IRIS level adjustment VR clockwise to get brighter picture.

IRIS ALC Adjustment

To select light metering method –

zTurn the IRIS ALC Adjustment VR counterclockwise for Average Metering.

zTurn the IRIS ALC Adjustment VR clockwise for Peak Metering.

7

Image 10
Contents EZ180 Page Table of Contents Safety Warning Handle the camera with careMain Features IntroductionSpecification EZ180Major Parts Names and Their Functions Installation Instructions Page Iris Level Adjustment Iris ALC AdjustmentFLFlickerless Normal/On BLC Back Light Compensation Normal/OnAGC Automatic Gain Control Off/On LL Line-Lock Off/OnHead Office