specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.
Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay.
Specify mask or unmask. When the setting is mask, alarm action is disabled during the filter time. When the setting is unmask, alarm action is enabled during the filter time.
The changes to filter of alarm action is saved by /api/param?application.event(Number).status=restart. Allowed users admin, operator
Getting Alarm Trigger from VN-V685/686/686B
Format /api/param?application.event(Number).trigger
Example When Getting Trigger of Alarm No. 1
/api/param?application.event(1).trigger
Example of Response application.event(1).trigger=m1&200 OK
Interpretation Acquire Trigger of the alarm action for the specified alarm number. Up to 5 alarm actions can be specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.
When only 1 Trigger is set:
m1 will be returned in the case of make for alarm input 1.
b1 will be returned in the case of break for alarm input 1.
m2 will be returned in the case of make for alarm input 2.
b2 will be returned in the case of break for alarm input 2.
v1 will be returned for motion detection of video. ncbws will be returned for IR filter OFF. ncbwe will be returned for IR filter ON.
efans will be returned for fan stop.
camera.position(num).status will be returned for preset position. "num" is from 0 to 99.
Example of Response application.event(1).trigger=v1&200 OK
When a combination of 2 Triggers are set, responses such as m1(10)b2 will be returned. The example indicates that trigger will be activated when break is invoked at alarm input 2 within 10 seconds after make is invoked at alarm input 1.
Example of Response application.event(1).trigger=m1(100)b2&200 OK
Allowed users admin, operator
Setting Alarm Trigger for VN-V685/686/686B