JVC VN-C3WU instruction manual Alarm IN/OUT connection, Cable connection and disconnection

Page 14

3. Alarm IN/OUT connection

Connect external devices to the alarm IN/OUT as shown below.

Sensor insert button

External

device OUT 1

External

device OUT 2

External

device

IN

Cable connection and disconnection

Press the sensor insert button when connecting and disconnecting cables. After connecting or disconnecting, make sure the sensor insert button returns to its original position.

About the alarm IN/OUT connection cables

Length: use cables with a length of 50m or less.

Recommended model: UL1007, UL1015 or equivalent cable with wire equivalent to AWG #22 - AWG #18.

Caution

External noise may affect the alarm working properly even with a cable length of 50m or less. In such cases, it is necessary to either change to the use of shielded cable to prevent influence by noise or to change the wiring route to avoid passing close to the source of the noise.

14

Image 14
Contents VN-C3WU Safety Precautions Information for USAKeep away from moisture Precautions for Safe and Proper USE Do not stand on this device Trademarks Before Saving Important ImagesContents Package Contents Operating Environment LAN environmentTo ensure correct usage Names of VN-C3WU parts VN-C3WU Installation and Setup Before starting installation and setup Installation and setup InstallationConnecting to a network About the power supply connection cableCable connection and disconnection Alarm IN/OUT connectionAbout the alarm IN/OUT connection cables Setting the VN-C3WU IP address 192.168.0.3Page Changing internal settings Page Page Page Page Restore to the original PC IP address VN-C3WU connection testPage VN-C3WU/Web User OperatorVN-C3WU live image Hyper link to the top Page Control Window Pan/Tilt/Zoom control Focus Lens setting windowZoom IrisPosition memory setting Position memory movementPage Control Window Image Quality Setting Camera Auto/Manual SettingsImage quality High Medium Low No. of frames Effect Alarm Settings Window Alarm output is not to be used Displaying live images How to link the VN-C3WU imagesDisplaying still image Page Troubleshooting Auto to Manual, and then back to Auto Specifications External dimensions Unit mmPage VN-C3WU V.NETWORKS