JVC WB-1550U, WB-1540U manual Assembling the Housing, Mount the desiccant

Page 13

Assembling the Housing

Safety Wire

1.

Main Housing Unit

Screw A (M4 x 6) x 3

2.

1. Mount the desiccant

Use a tape to adhere the supplied desiccant to the interior of the lower housing.

CAUTION:

Fogging may occur when there are drastic temperature changes. In this case, continue using without turning off the power.

Pay attention when handling the desiccant in order to maintain its effectiveness.

Do not remove it from the bag until you are about to use it.

Do not wet it or touch it with wet hands.

Assemble promptly upon adhering the desiccant.

Be sure to replace the desiccant during maintenance.

 

Lower Housing

 

Position Mark

Desiccant

Gasket

 

3.

 

Gasket Gland

 

Screw B (M4) x 8

2. Mount the lower housing

Mount the lower housing that is dismantled in Step 2.

(A pg. 10) to the main housing unit using the 3 Screw A (M4 x 6).

Do so by aligning the position marks of the lower housing and the main housing unit.

3. Mount the gasket and gasket gland

Mount the gasket and gasket gland that are dismantled in Step 1. (A pg. 10) of the housing disassembly procedure to the lower housing using the 8 Screws B (M4).

CAUTION:

During assembly, ensure that wires and cables are not caught in the housing.

Do not exert force unnecessarily on the gasket or twist it during mounting.

Check to ensure that the gasket is in close contact with the camera.

Mounting the Housing to the wall

Anchor Bolt

(M8, 35 mm and above)

Washer

Nut

Safety Wire

Installation Position1. 2.

152

126

63

 

 

 

 

 

 

 

12

0

 

 

 

 

 

 

 

3

 

 

 

 

 

 

1. Drill a hole into the wall.

Drill a hole (R 45 mm) for inserting the connection cable. (Refer to left fig.)

2. Affix anchor bolts onto the wall.

Affix 4 anchor bolts (M8, 35 mm and above) for attaching the housing. (Refer to left fig.)

Affix an anchor bolt for attaching the safety wire, in the middle (about 60 mm from both ends) of the 2 upper anchor bolts, 30 mm from the top. (Refer to left fig.)

3. Mount the safety wire and arm to the wall.

Mount the safety wire attached to the housing, to the anchor bolts using the nut and wire.

Use the nut and wire to mount the housing onto the wall.

176

202

60

13

Image 13
Contents WB-1540U WB-1550U Important Safeguards Information for USA  Information For USA and CanadaOperating Precautions Table of ContentsVN-C625U and VN-C655U Systems System ExampleDismantle the lower housing Disassembling the HousingDismantle the gasket and gasket gland Mounting the Camera VN-C625U Mounting the Housing to the wall Assembling the HousingOpen the cable connection cover Bind cable using a waterproof tapeConnect each cable Fasten the cables in the interior of the armDismantle the rubber gasket of the camera’s ceiling mount Procedures Before Mounting the CameraDismantle the rubber gasket in the interior of the camera Connect the AC 24 V output cable to the camera Mounting the Camera TK-C655E and TK-C676EMounting the Camera VN-C655U Mount the desiccant Open the cable connection cover  Mass 5.0 kg  Accessories Specifications General WB-1540U/WB-1550U Outdoor Housing