Interpretation Acquire the unit of interval for accessing the NTP server. "min", "hour" or "day" is returned. Allowed users admin, operator, user
Setting Access Interval Unit of SNTP for VN-V25/26
Format /api/param?network.ntp.unit=data
Example /api/param?network.ntp.unit=day
Example of Response
network.ntp.unit&202 Accepted(network.ntp.status=restart)
Interpretation Change the unit of interval for accessing the NTP server. Specify "min", "hour" or "day". To validate the change, use "network.ntp.status=restart" API.
Allowed users admin, operator
Getting Time from VN-V25/26
Format /api/param?system.date
Example of Response system.date=20050614171537&200 OK
Interpretation Acquire the time from the
Allowed users admin, operator, user
Setting Time for VN-V25/26
Format /api/param?system.date=data
Example /api/param?system.date=20050614171537
Example of Response system.date&200 OK
Interpretation Change the time of the
Allowed user admin
Getting Timezone from VN-V25/26
Format /api/param?system.timezone
Example of Response system.timezone=Pacific&200 OK
Interpretation Acquire the timezone from
Timezone Character String | Description |
Timezone that is 12 hours earlier than the Greenwich Mean Time. |
65