Page 145

Chapter 7 Circuits and Tunnels

7.15 Reconfigured Circuits

Circuits types must be a compatible.

Circuit directions must be compatible. You can merge a one-way and a two-way circuit, but not two one-way circuits in opposing directions.

Circuit sizes must be identical.

Circuit end points must send or receive the same framing format.

The merged circuits must become a DISCOVERED circuit.

If all connections from the master circuit and all connections from the merged circuits align to form one complete circuit, the merge is successful. If all connections from the master circuit and some, but not all, connections from the other circuits align to form a single complete circuit, CTC notifies you and gives you the chance to cancel the merge process. If you choose to continue, the aligned connections merge successfully into the master circuit, and unaligned connections remain in the original circuits. All connections in the completed master circuit use the original master circuit name.

All connections from the master circuit and at least one connection from the other selected circuits must be used in the resulting circuit for the merge to succeed. If a merge fails, the master circuit and all other circuits remain unchanged. When the circuit merge completes successfully, the resulting circuit retains the name of the master circuit.

7.15 Reconfigured Circuits

You can reconfigure multiple circuits, which is typically necessary when a large number of circuits are in the PARTIAL status. When you reconfigure multiple circuits, the selected circuits can be any combination of DISCOVERED, PARTIAL, DISCOVERED_TL1, and PARTIAL_TL1 circuits. You can reconfigure tunnels, CTC-created circuits, and TL1-created circuits. The Reconfigure command maintains the names of the original cross-connects.

Use the CTC Tools > Circuits > Reconfigure Circuits command to reconfigure selected circuits. During reconfiguration, CTC reassembles all connections of the selected circuits into circuits based on path size, direction, and alignment. Some circuits might merge and others might split into multiple circuits. If the resulting circuit is a valid circuit, it appears as a DISCOVERED circuit. Otherwise, the circuit appears as a PARTIAL or PARTIAL_TL1 circuit.

Note PARTIAL tunnel circuits do not split into multiple circuits during reconfiguration.

7.16 Server Trails

A server trail is a non-DCC link across a third-party network that connects two CTC network domains. A server trail allows circuit provisioning when no DCC is available. You can create server trails between any two optical or DS-3 ports. The end ports of a server trail can be different types. Server trails are not allowed on DCC-enabled ports.

The server trail link is bidirectional and can be VT1.5, VT2, STS1, STS-3c, or STS-12c; you cannot upgrade an existing server trail to another size. A server trail link can be one of the following protection types: Preemptible, Unprotected, and Fully Protected. The server trail protection type determines the protection type for any circuits that traverse it. PCA circuits will use server trails with the Preemptible attribute.

Cisco ONS 15600 Reference Manual, R7.2

7-27

Image 145
Contents Corporate Headquarters Cisco ONS 15600 Reference ManualCisco ONS 15600 Reference Manual, Release Iii N T E N T STSC Network-Level Indicators SFP Modules TSC Card Database Vii Path Protection CircuitsViii Two-Fiber Blsr to Four-Fiber Blsr10.1 Any Service Any Port Card Application 10.2 Snmp Bandwidth Xii Environmental Specifications A-4Xiii CTC Default Settings C-39Xiv Bay Label Xvi Legal Disclaimer TabXvii Path-Protected Mesh Network Ppmn Virtual RingXviii OSI/IP Scenario 5 GNE Without an OSI DCC ConnectionXix B L E SLink Icons Xxi Alarm WindowXxii Power and Noise Limited Performances A-14Xxiii About this ManualDocument Objectives Revision HistoryAudience Related DocumentationConvention Application Document ConventionsXxv Xxvi Warnung Wichtige SicherheitshinweiseAviso Instruções Importantes DE Segurança Avvertenza Importanti Istruzioni Sulla SicurezzaXxvii Xxviii Xxix GEM Disse AnvisningerXxx Obtaining Optical Networking Information Where to Find Safety and Warning InformationCisco Optical Networking Product Documentation CD-ROM XxxiXxxii Shelf and Backplane Hardware Installation OverviewBay Installation ONS 15600 with Dollies Installed ONS 15600 Front Door Front DoorFront door also has a Class I laser warning Figure Rear Covers6shows the bus bar covers Cable Routing Customer Access PanelRear of the ONS 15600, Including the CAP 8shows the CAP faceplate External Alarm and Control Contact Installation Alarm, Timing, LAN, and Craft Pin ConnectionsVisual and Audible Alarms Alarm Cutoff and PDU Alarms Timing Installation4 TL1 Craft Interface Installation LAN InstallationSee , Timing, for more information Power and Ground Description Power Distribution Unit11 Front and Rear Bay Ground Holes Air Filter Fan-Tray Assembly13 Air Filter and one Fan Tray Pulled Out Fan Speed and FailureCard Slot Requirements Cards and SlotsCondition Watts Amps BTU/Hr 157Card Ports Line Rate per Port Asap Card Cables17show the OGI pin breakout for the OC-48 card OGI CablesOptical Card Cable Routing Card ReplacementPage Page Card Summary Card OverviewCard Description For Additional Information Card R1.0 R1.x.x R5.0 R6.0 R7.0 R7.2 Card CompatibilityTSC Card TSC Slots and ConnectorsTSC TSC Faceplate and Block DiagramTSC Network-Level Indicators TSC Card-Level IndicatorsIndicator Color Definition Ssxc Switch Matrix TSC Push-Button SwitchesSsxc Card Push-Button FunctionSsxc Faceplate and Block Diagram Ssxc Slots and Connectors1 OC48/STM16 LR/LH 16 Port 1550 Slots and Connectors Ssxc Card-Level IndicatorsOC48/STM16 LR/LH 16 Port 1550 Card OC48/STM16 LR/LH 16 Port 1550 Faceplate and Block Diagram 2 OC48/STM16 LR/LH 16 Port 1550 Faceplate and Block Diagram4 OC48/STM16 LR/LH 16 Port 1550 Network-Level Indicators 3 OC48/STM16 LR/LH 16 Port 1550 Card-Level Indicators5 OC48/STM16 LR/LH 16 Port 1550 Card OGI Connector Pinout Indicator Color DescriptionOC48/STM16 SR/SH 16 Port 1310 Card 1 OC48/STM16 SR/SH 16 Port 1310 Slots and ConnectorsOC48/STM16 SR/SH 16 Port 1310 Faceplate and Block Diagram 2 OC48/STM16 SR/SH 16 Port 1310 Faceplate and Block Diagram4 OC48/STM16 SR/SH 16 Port 1310 Network-Level Indicators 3 OC48/STM16 SR/SH 16 Port 1310 Card-Level Indicators5 OC48/STM16 SR/SH 16 Port 1310 Card OGI Connector Pinout 12lists the OC48/STM16 SR/SH card OGI connector pinoutsOC192/STM64 LR/LH 4 Port 1550 Card 1 OC192/STM64 LR/LH 4 Port 1550 Slots and ConnectorsOC192/STM64 LR/LH 4 Port 1550 Faceplate and Block Diagram 2 OC192/STM64 LR/LH 4 Port 1550 Faceplate and Block Diagram4 OC192/STM64 LR/LH 4 Port 1550 Network-Level Indicators 3 OC192/STM64 LR/LH 4 Port 1550 Card-Level Indicators5 OC192/STM64 LR/LH 4 Port 1550 Card OGI Connector Pinout OC192/STM64 SR/SH 4 Port 1310 Card 1 OC192/STM64 SR/SH 4 Port 1310 Slots and Connectors3 OC192/STM64 SR/SH 4 Port 1310 Card-Level Indicators 2 OC192/STM64 SR/SH 4 Port 1310 Faceplate and Block Diagram5 OC192/STM64 SR/SH 4 Port 1310 Card OGI Connector Pinout 4 OC192/STM64 SR/SH 4 Port 1310 Network-Level IndicatorsAsap Card SFP on STS192 Asap ConnectorsSTS3c STS6c STS9c STS12c STS18c STS24c STS36c STS48c OC3Asap Covers and Plugs Asap Card Faceplate and Block Diagram with 4PIOs Installed9shows the 1PIO module faceplate 5 1PIO Module FaceplateAsap Card Port-Level Indicators Asap Card-Level IndicatorsPort PPM Slot Asap Card Port Numbering 4PIO InstalledSFP Modules Asap Card Port Numbering 1PIO InstalledONS 15600 SONET/SDH CardONS-SE-2G-L2 ONS-SE-Z1Asap 1PIO only XFP DescriptionONS-XC-10G-S1 ONS-XC-10G-L2 PPM Provisioning Filler Card17shows the Filler card body and faceplate Page Optical Port Protection Card ProtectionType Ports Description ONS 15600 in a 1+1 Protected ConfigurationUnprotected Ports External Switching CommandsCard Protection External Switching Commands CTC Software Delivery Methods CTC Software Installed on the TSC CardCTC Software Installed on the PC or Unix Workstation CTC Installation OverviewArea Requirements PC and Unix Workstation RequirementsRAM CTC Login Legal Disclaimer Tab Legal DisclaimerCTC Window Login Node GroupNode View Port Color Service State DescriptionCTC Card Colors Card Color StatusNode View Tabs Node View Card ShortcutsOOS-MA,DSBLD IS-NRTab Description Subtabs Network ViewCTC Node Colors Color Alarm StatusNode icon colors indicate the node status Table Link Consolidation Network View Tabs6lists the tabs and subtabs available in the network view Icon DescriptionPPC icon Server Trail icon Card ViewCTC Card View Showing an OC-192 Card View or Card Tab Subtabs Export and Print CTC DataTSC Card Database CTC Card ResetSoftware Load Revert User Privileges and Policies Users IDs and Security LevelsOSI User Privileges by Security LevelBlsr Snmp Edit/ResetSubtab Actions Retrieve Maintenance Provisioning Superuser Security Policies Idle User TimeoutSuperuser Privileges for Provisioning Users Default Idle Time Superuser Password and Login PrivilegesAudit Trail Radius Security Radius AuthenticationAudit Trail Log Entries Audit Trail CapacitiesShared Secrets Group Examples Page Timing Parameters TimingNetwork Timing Message Quality Description Synchronization Status MessagingPRS STUST3 ST2SMC ST4Circuits and Tunnels Circuit Properties OverviewONS 15600 Circuit Window in Network View Starting Concatenated STS Time Slot Assignments103 100106 109Circuit Status Circuit States 2F Blsr Circuit Protection Types2F-PCA DRICircuit Information in the Edit Circuit Window Purple Port Color Service StateCyan Blue Detailed Circuit Map Showing a Terminal Loopback DCC Tunnels Cross-Connect Card BandwidthTraditional DCC Tunnels Sonet BytesPath Protection Circuits Multiple Destinations for Unidirectional CircuitsIP-Encapsulated Tunnels Editing Path Protection Selectors Viewing Path Protection Switch Counts Protection Channel Access CircuitsBlsr STS Squelch Table Blsr STS and VT Squelch TablesBlsr VT Squelch Table Path TraceCard Receive Transmit Automatic Circuit RoutingSecondary Sources and Destination Bandwidth Allocation and RoutingNo. of Sources No. of Drops Connection Type Manual Circuit RoutingDouble path Two-wayOne-way Constraint-Based Circuit RoutingHead end Drop and continueRolls Window Bridge and RollState Description Roll StatusSingle Destination Roll Single and Dual Rolls12illustrates a dual roll on the same circuit Two Circuit Bridge and Roll Merged CircuitsProtected Circuits Server Trails Reconfigured CircuitsCircuits and Tunnels Server Trails Sonet Topologies and Upgrades Bidirectional Line Switched Rings Point-to-Point and Linear ADM ConfigurationsTwo-Fiber BLSRs Four-Node, Two-Fiber Blsr Four-Node, Two-Fiber Blsr Traffic Pattern Sample Four-Fiber BLSRs Four-Node, Four-Fiber Blsr Four-Fiber Blsr Span Switch OC-48 STS N 1 PT OC-192 N PT Blsr BandwidthOC-48 STS 1-48 Fiber N 1 PT OC-192 STS 1-192 Fiber N PT Blsr Fiber ConnectionsConnecting Fiber to a Four-Node, Two-Fiber Blsr Path-Protected Mesh Networks 10 Connecting Fiber to a Four-Node, Four-Fiber Blsr11 Path-Protected Mesh Network In-Service Topology Upgrades Two-Fiber Blsr to Four-Fiber Blsr Point-to-Point or Linear ADM to Two-Fiber BlsrAdd or Remove a Node from a Topology IP Networking Overview Management Network ConnectivityScenario 1 CTC and ONS 15600s on the Same Subnet ONS 15600 IP Addressing ScenariosWhat to Check Sonet Ring Scenario 2 CTC and ONS 15600s Connected to RouterONS 15600 Proxy Server section on Scenario 3 Using Proxy ARP to Enable an ONS 15600 GatewayScenario 3 Using Proxy ARP Scenario 4 Default Gateway on CTC ComputerScenario 4 Default Gateway on a CTC Computer Scenario 5 Using Static Routes to Connect to LANs81205 Scenario 5 Static Route with Multiple LAN Destinations Scenario 6 Using OspfScenario 6 Ospf Enabled Scenario 6 Ospf Not Enabled Scenario 7 Provisioning the ONS 15600 Proxy Server Proxy Server Gateway Settings Firewall Not EnabledGNE Setting ONS 15600 GNE ONS 15600 ENEENE Ospf LAN81209 Firewall Enabled Packets Arriving At Accepts Rejects 13 Nodes Behind a Firewall Scenario 8 Dual GNEs on a Subnet15 Scenario 8 Dual GNEs on the Same Subnet 16shows a network with dual GNEs on different subnets Provisionable PatchcordsMXP2.5G10G MXP2.5G10E Routing TableTXPPMR2.5G OC-192Entry Destination Mask Gateway Interface 6shows sample routing entries for an ONSPort Function Action External FirewallsFTP Http3082 Raw TL1 3083 TL1Management Network Connectivity Open GNE Open GNE18 Proxy and Firewall Tunnels for Foreign Terminations 19 Foreign Node Connection to an ENE Ethernet Port TCP/IP and OSI NetworkingOSI Model IP Protocols OSI Protocols IP-OSI Mediation Point-to-Point ProtocolOSI Connectionless Network Service Link Access Protocol on the D ChannelField Definition Description SEL OSI Routing Intermediate System-to-Intermediate System End System-to-Intermediate System ProtocolField Abbreviation Size bytes Description TarpTarp Processing Type Description ProcedurePDU Tarp Loop Detection Buffer Default Range Timer Description SecondsProcess General Tarp Flow Manual Tarp Adjacencies 6 TCP/IP and OSI MediationManual TID to Nsap Provisioning TD Protocol Flow OSI Virtual RoutersIP-over-CLNS Tunnels Routing Mode Router Router 2 Per area Per isFT-TD Is L1/L225 IP-over-CLNS Tunnel Flow Provisioning IP-over-CLNS TunnelsStep Purpose IP-Over-CLNS Tunnel Scenario 1 ONS Node to Other Vendor GNECTC IP-Over-CLNS Tunnel Scenario 2 ONS Node to RouterIP Over Clns Tunnel Scenario 2 ONS Node to Router Management Network Connectivity IP-over-CLNS Tunnels 9 OSI/IP Networking Scenarios CTC/CTM IP DCN ONS GNE CTC/CTM IP OSS IP DCN ONS GNE OSI GNE CTC/CTM IP OSS 9.4 OSI/IP Scenario 4 Multiple ONS DCC Areas 33 OSI/IP Scenario 4 Multiple ONS DCC Areas 9.5 OSI/IP Scenario 5 GNE Without an OSI DCC Connection34 OSI/IP Scenario 5 GNE Without an OSI DCC Connection OSI/IP Scenario 7 -36 shows an example of a European network ONS NE Cisco ONS 15600 Reference Manual, R7.2 OSI/LAP-D Tab Actions OSI Provisioning in CTCGE LX Any Service Any Port Card Application10-1 GFP Transport Functionality10-2 ONS 15600 Ethernet Frame Transport 10-3Frame Size Ethernet Rates and MappingEncapsulations Path and Circuit SizesOversubscription Protocols over EthernetBridge Control Protocol PPP Half BridgeVlan Buffering and Flow Control10-6 10-7 Autonegotiation10-8 Gigabit EtherChannel/IEEE 802.3ad Link Aggregation11-1 Alarms, Conditions, and HistoryDescription Description of the alarm 1describes in the information in the Alarms windowColumn Information Recorded 11-211-3 Color DescriptionAlarm-Affected Circuits Alarm WindowMON Object Optical Syntax and Examples Button Action11-5 Conditions Window5shows the actions you can perform in the Conditions window Conditions Window ActionsButton Retrieve FilterDescription Description of the condition History Window11-7 11-8 7describes the information in the History windowAlarm History Actions Alarm ProfilesAlarm Profile Window 11-9Button Description Alarm Profile Buttons11-10 Alarm Severity Option Alarm Profile EditingAlarm Profile Applications Row Display OptionsAlarm Suppression Alarm Filter11-12 Alarms Suppressed for Maintenance External Alarms and ControlsAlarms Suppressed by User Command 11-13Virtual Wires for External Alarms in Mixed Networks External Alarm InputExternal Control Output 11-1411-15 Virtual Wires Seen from an ONS11-16 12-1 Threshold Performance MonitoringLine Terminating Equipment Intermediate-Path Performance Monitoring12-2 12-3 2shows the Provisioning Sonet STS tabs for an OC-48 card12-4 Pointer Justification CountParameter Definition Performance-Monitoring Parameter Definitions12-5 12-6 12-7 12-8 12-9 Optical Card Performance MonitoringSection NE Line NE 3lists the near-end and far-end section layer PMsLine FE Optics NE 3 STS Path FE PSC 1+1Physical Layer Parameters Asap Card Performance MonitoringAsap Card Optical Performance Monitoring Parameters STS SES-PAsap Card Ether Port Statistics Window Asap Card Ethernet Performance Monitoring ParametersParameter Meaning 12-1212-13 12-14 12-15 Asap Card Ether Ports Utilization WindowAsap Card POS Ports Statistics Parameters Asap Card Ether Ports History WindowMaxBaseRate Time Interval Number of Intervals DisplayedAsap Card POS Ports History Window Asap Card POS Ports Utilization Window12-17 12-18 13-1 Snmp Overview13-2 Basic Snmp ComponentsExample of the Primary Snmp Components 13-3Snmp Version Support Snmp External Interface RequirementSnmp Message Types Operation DescriptionIETF-Standard MIBs for ONS Snmp Management Information BasesThis section contains the following information Number Module Name Title/CommentsProprietary ONS 15600 MIBs Snmp Trap ContentHC-RMON-MIB 13-6Variable Trap Bindings Generic and Ietf Traps13-7 RFC EntConfigChange from RFC AuthenticationFailure From RFC13-8 13-9 13-10 13-11 Proxy Over Firewalls13.8.2 64-Bit Rmon Monitoring over DCC Remote MonitoringHC-RMON-MIB Support Row Creation in MediaIndependentTableHistory Control Rmon Group Ethernet Statistics Rmon GroupRow Creation in historyControlTable Alarm Rmon GroupRow Deletion in historyControl Table Ethernet History Rmon GroupRow Deletion in alarmTable Alarm TableEvent Rmon Group Event Table13-16 Bandwidth Shelf SpecificationsSlot Assignments Dimensions ConfigurationsCards Cisco Transport ControllerExternal LAN Interface Alarm Interface8 TL1 Craft Interface Modem InterfacePower Specifications Environmental SpecificationsDatabase Storage Card Type Card Name WattsTSC Card Specifications Card SpecificationsTable A-3shows the TSC card specifications Specification Type Description3 OC48/STM16 LR/LH 16 Port 1550 Specifications Ssxc SpecificationsTable A-4shows the Ssxc card specifications Specification Type Description 4 OC48/STM16 SR/SH 16 Port 1310 Specifications OGI 5 OC192/STM64 LR/LH 4 Port 1550 Specifications6 OC192/STM64 SR/SH 4 Port 1310 Specifications Table A-9shows the Asap card specifications Asap SpecificationsFiller Card Specifications SFP/XFP SpecificationsTransmitter Output Receiver Input Power Min/Max dBmInterface Wavelength Table A-13lists the available Dwdm SFPsWavelength Fiber Type Cable Distance PRBS23State Qualifier Definition Service StatesOOS-AU OOS-AUMASecondary State Definition Administrative StatesCard Service State Transitions Service State TransitionsCurrent Service State Action Next Service State OOS-AU,MEA & MT OOS-AU,MEAOOS-AUMA,MT & UEQ OOS-AUMA,MT & SwdlPort and Cross-Connect Service State Transitions OOS-AUMA,FLT & Lpbk OOS-AU,AINS & FLTOOS-MA,LPBK & MT OOS,MT Loopback Alarm/condition is raisedOOS,DSBLD Put the port or cross-connect Page Network Element Defaults Description Network Element DefaultsConfiguration Defaults Card Default SettingsDefaults by Card Threshold Defaults3.1 OC1924 Card Default Settings Default Name Default Value Default DomainOPR-LOW, OPR-LOW + 1, OPR-LOW LBC-LOW, LBC-LOW + 1, LBC-LOWOPT-LOW, OPT-LOW + 1, OPT-LOW Default Name Default Value Default Domain Default Name Default Value Default Domain Default Name Default Value Default Domain LBC-LOW, LBC-LOW + 3.2 OC4816 Card Default SettingsOPR-LOW, OPR-LOW + OPT-LOW, OPT-LOW +Default Name Default Value Default Domain Default Name Default Value Default Domain Default Name Default Value Default Domain OOS,DSBLD IS, OOS,DSBLD, OOS,MT IS,AINS Asap Card Default SettingsIS,AINS IS, OOS,DSBLD, OOS,MT ASAP4.config.oc192.line.SyncMsgIn ASAP4.config.oc192.line.StateASAP4.config.oc192.sts.IPPMEnabled ASAP4.config.oc3.line.SyncMsgInASAP4.physicalthresholds.oc12.warning.1day.LBC-HIGH 200 % ASAP4.physicalthresholds.oc3.alarm.OPR-HIGH 200 % ASAP4.physicalthresholds.oc48.warning.15min.OPT-HIGH 120 % Default Name Default Value Default Domain Default Name Default Value Default Domain Default Name Default Value Default Domain Default Name Default Value Default Domain Default Name Default Value Default Domain Default Name Default Value Default Domain Default Name Default Value Default Domain Default Name Default Value Default Domain Default Name Default Value Default Domain Default Name Default Value Default Domain Default Name Default Value Default Domain Default Name Default Value Default Domain Node Default Settings NODE.circuits.State Default Default Name Value DomainIS,AINS OOS,DSBLD OOS,MT False TrueNODE.general.UseDST NODE.network.general.AlarmMissingBackplaneLANTrue False ProxyOnlyNoNODE.osi.tarp.LANStormSuppression NODE.osi.tarp.L2DataCacheNODE.osi.tarp.LDB NODE.osi.tarp.PDUsL2PropagationNODE.protection.blsr.SpanRevertive NODE.security.passwordAging.EnforcePasswordAging ESF ESF, D4 B8ZS B8ZS, AMIST3EREST TncressRES=DUS NODE.timing.general.Revertive Time ZonesNODE.timing.general.SSMMessageSet Generation GMT Greenwich Mean Time GMTCTC Default Settings True TRUE, False Default Default Name Value Default DomainIN-1 IN-2 BitsCTC CorbaIN-3 DCN DCCDhcp DwdmIN-5 IN-6 IiopLAN JREIN-7 NPJC-Pgen parameter Viewing popup information NPJC-Pdet parameterNsap IN-8PM read points Power requirements TimingCable breakout RadiusLAP-D OSI PIMSntp SSMRmon PST B-1 Pstq B-1IN-11 SSM SST SonetIN-12 IN-13 TCAIN-14
Related manuals
Manual 14 pages 28.36 Kb Manual 38 pages 50.74 Kb Manual 10 pages 50.2 Kb

ONS 15600 specifications

Cisco Systems ONS 15600 is a highly versatile optical networking platform designed to meet the demands of modern telecommunications and data services. This multiservice edge platform supports various transmission mediums and offers a wide array of features that enable efficient data transport. Ideal for service providers and large enterprises, the ONS 15600 is engineered to provide scalable and reliable optical transport solutions.

One of the notable features of the ONS 15600 is its capability to support multiple protocols, including SONET/SDH, Ethernet, OTN, and legacy TDM services. This flexibility allows users to tailor their networks according to specific service requirements while ensuring interoperability with existing infrastructure. The platform is designed to facilitate seamless service migration, accommodating both legacy and next-generation services.

The modular architecture of the ONS 15600 enhances its scalability. It allows for easy expansion by incorporating additional line cards or interface modules without requiring significant downtime. This modularity ensures that service providers can evolve their networks over time, responding to increasing bandwidth demands and new service offerings with ease.

Incorporating advanced technologies, the ONS 15600 employs Dense Wavelength Division Multiplexing (DWDM), significantly increasing the capacity of fiber networks by allowing multiple signals to be transmitted simultaneously over a single optical fiber. This capability helps to optimize fiber utilization and reduce operational costs. In addition, the platform supports Optical Transport Network (OTN) for improved error detection and correction, contributing to higher reliability and performance.

Another key characteristic of the ONS 15600 is its robust management capabilities. The platform can be managed through Cisco's Optical Networking Manager (ONM), providing a centralized interface for network configuration, monitoring, and troubleshooting. This enhances operational efficiency and minimizes downtime, allowing service providers to focus on delivering quality services to their customers.

The ONS 15600 also prioritizes security, offering various features like encryption and access control to safeguard sensitive data during transmission. With its combination of scalability, flexibility, and security, the Cisco ONS 15600 stands out as a reliable choice for organizations looking to enhance their optical networking capabilities while meeting the evolving demands of the digital landscape. Its commitment to quality and performance makes it a cornerstone of modern optical networks.