3M 3900 owner manual Solving problems, Problem Cause Action

Page 25

Solving problems

Problem

Cause

Action

No alarm, no mechanical

No power at receptacle.

Reset facility circuit breaker.

counter, no red power indicator

 

 

Power cord disconnected at receptacle.

Plug power cord into receptacle.

on the electronics enclosure.

 

 

 

System fuse open.

Replace fuse in power entry connector. See

 

 

fuse replacement procedure.

 

Power turned off at electronics enclosure.

Turn key switch to On.

 

 

 

 

System failure.

Place a service call.

 

 

 

No alarm, no mechanical

Processor requires reset.

Turn the key switch off, wait 5 seconds,

counter, power indicator on.

 

then turn the switch on.

 

System failure.

Place a service call.

 

 

 

No alarm, patron counter

Strips in book desensitized or missing.

Resensitize books, or install a Tattle-Tape

works.

 

security strip in the book.

 

Metal objects too close to lattice.

Move all metal to minimum distance of 18

 

 

inches from the lattices.

 

System failure.

Place a service call.

 

 

 

Unwanted alarms.

Protected material from another library or a

Identify material that caused the alarm.

 

retail store.

 

 

Failure to desensitize strips properly.

Check desensitizing process and training.

 

 

 

 

Miscellaneous metallic objects.

Infrequent unwanted alarms are possible

 

 

from some metal objects .

 

System failure.

Place a service call.

 

 

 

Reduced coverage, no alarm,

Metal objects too close to lattice.

Move all metal to minimum distance of 18

patron counter works.

 

inches from the lattices.

 

Electrical interference.

Remove possible sources of electrical

 

 

interference such as computers, copiers,

 

 

TVs, electronic devices, or energy

 

 

management systems.

 

Incomplete walk-through test.

Test the system by walking completely

 

 

through the corridor.

 

Books not properly resensitized.

Resensitize book, check sensitizing method

 

 

and staff training.

 

System failure.

Place a service call.

 

 

 

Alarm indicator illuminated or

Metal objects too close to a lattice.

Move all metal objects to a minimum of 3

intermittent with no traffic in

 

feet from the lattice.

corridor.

 

 

Marked book or strips too close to lattice.

Move the marked books to a minimum of 3

 

 

 

feet from the lattice.

 

 

 

 

Electrical interference.

Eliminate source of interference.

 

 

 

 

System failure.

Place a service call.

 

 

 

Copyright © 2008. 3M. All rights reserved.

17

Image 25
Contents Detection System Model 3900 Series Page Contents Contents Copyright 2008, 3M. All rights reserved Safety Information Safety messages Safety labels FCC/Industry Canada/European/Australia EMC compliance Global leader in library systems products IntroductionWhat this means to you Introduction Copyright 2008 M. All rights reserved Hands-on practice Training your staffReview of your library’s security policies Alarm log What to do when the alarm soundsHow the system works How the system works Copyright 2008 M. All rights reserved Models 3901 System configurationsModels 3911 Physical specifications Machine characteristicsPower requirements ConstructionEnvironmental requirements operation IndicatorsEnvironmental requirements storage Detection zoneVisual Alarm outputsPage Lattice and base Cleaning InstructionsPhotocell lens and reflector Cleaning Instructions Copyright 2008 M. All rights reserved System Operation Fuse replacementTurning your system on and off Verifying system operationSystem Operation Copyright 2008 M. All rights reserved Problem Cause Action Solving problemsSolving problems Copyright 2008 M. All rights reserved Effective WarrantyWarranty Copyright 2008 M. All rights reserved Alarm reason Detection system alarm logPage 3M Service phone numbers 3M ServiceSystem information 3M Library Systems