Manual
ATTENTION
Safety First!
Be sure to disconnect the power cord before installing and/or wiring your Moxa switch.
This device has UL508 approval. Use copper conductors only, 60/75°C, Tighten To 4.5
ATTENTION
Safety First!
Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size. If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment.
You should also pay attention to the following:
yUse separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point.
NOTE: Do not run signal or communications wiring and power wiring in the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately.
yYou can use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.
yKeep input wiring and output wiring separated.
yIt is strongly advised that you label wiring to all devices in the system when necessary.
Grounding Moxa VPort 351
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted to a
- 13 -