XD642W OPERATION
Troubleshooting
Problem | Cause | Action |
Unit will not turn on | Yellow wire not connected or incorrect voltage | Check connections for proper voltage |
(no power) | Red wire not connected or incorrect voltage | (11~16VDC) |
| Black wire not connected | Check connection to ground |
| Fuse blown | Replace fuse |
Unit has power | Speaker wires not connected | Check connections at speakers |
(but no sound) | One or more speaker wires touching each | Insulate all bare speaker wires from |
| ||
| other or touching chassis ground | each other and chassis ground |
Unit blows fuses | Yellow or red wire touching chassis ground | Check for pinched wire |
| Speaker wires touching chassis ground | Check for pinched wire |
| Incorrect fuse rating | Use fuse with correct rating |
Excessive skipping | Unit is not mounted correctly or backstrap is | Check mounting sleeve and backstrap |
| not secure | support |
| Physical defect in media (CD, | Check media for scratches |
Disc read error | Press eject or RESET | |
on display |
|
|
Focus error or disc is in upside down | Press eject or RESET | |
on display |
|
|
Unit will not accept | CD mechanism position out of alignment | Press EJECT for 3 seconds to reset |
a disc |
| CD mechanism position |
|
|
|
| CD transit screws still in place | Remove 2 transit screws located on |
|
| top of the unit |
|
|
|