Samson D1500, D1200 owner manual Controls and Functions

Page 7

Controls and Functions

7

10

9 8

11

12 13

7.GAIN Control - This control adjusts the overall signal level at the input of the internal power amplifi- er. This control does not affect the signal sent to the THRU outputs.

8.SIGNAL Indicator - The green SIGNAL LED lights whenever signal is present at the D1200’s inputs.

9.LIMITER Indicator - This yellow LED lights when the amp is near the clipping point and the limiter is engaged. If the LIMITER indicator lights frequently, turn down the GAIN control on the Auro sub- woofer or turn down the signal at the source, until the indicator does not light anymore, or lights only occasionally with high signal peaks.

10.PROTECT Indicator - This LED lights RED when the amp overheats or other problems have been de- tected. If the PROTECT indicator lights due to the level being too high, the amplifier will limit the audio and lower the output level. Turn the GAIN control down until the PROTECT indicator is no longer lit. When the unit cools, the amplifier will raise the level back up.

11.LPF (Hz) - Adjusts the low frequency filter end range of the subwoofer from 80Hz-200Hz. This set- ting does not affect the signal sent to the THRU outputs.

12.DSP - The Auro D1200 DSP has three EQ contour curves: NORMAL, DEEP, and BOOST. The NOR- MAL setting produces the standard frequency response for the subwoofer and works best for most applications. BOOST enhances frequencies at 100Hz to add punch and strengthen the kick drum frequency band. The DEEP setting extends the low frequencies down to widen the range of the subwoofer.

Note: While the DEEP setting might increase the low frequency response of the Auro D1200, low frequencies use more power and reduce the overall headroom of the amplifier.

13.POLARITY Switch - Use this switch to set the polarity of the amplified signal. In the NORMAL set- ting, there is no change to the signal. When the switch is set to the in REVERSE setting, the sig- nal’s polarity is changed by 180°. The setting of the POLARITY switch has no effect on the signal sent to the THRU outputs.

14.AC INPUT - Connect the supplied standard IEC AC power cable here.

15.POWER Switch - Switches on the Auro D1200 main power.

16.Voltage Switch - Slide to change the operating voltage from 115 to 230 volts.

14

16

15

Auro Active Subwoofer

7

Image 7
Contents Auro D1200 Auro D1500 Avis Risque DE Choc Électronique NE PAS Ouvrir Important Safety InformationIntroduction Auro D1200 and D1500 Features Quick Start Inputs and Outputs Controls and Functions Mono Sub Operation Stereo Sub Operation Polarity Setting the Low Pass Filter LPFAuro D1200 Specifications