Sanyo PID-42AE1, PID-42AS1 instruction manual Installation Mode, Setting Procedure, Dcr

Page 13

GB

INSTALLATION MODE

GB

Installation Mode

Address

Set the address for the LCD monitor (0 ~ 999)..

Installation Mode

On program Tuner Menu Max Volume Winter mode RC inhibition Child Lock Address Baud rate Panel protection AV Auto shut off Network Standby On Timer Function LED light setting

DCR Network initial Temperature Error IP Address Subnet Gateway

DNS

Select Adjust

G2.02 0000

Off

Off

63

Off

Off

Off

0

19200

Off

Off

On

Off

Off

Off

>>>

0

000000000000

000000000000

000000000000

000000000000

MENU Exit

Setting the monitor address in RS232 mode

Each monitor can have a specific Address, which helps command that monitor individually and will not effect to other monitors con- nected to a controlling PC Address format command..

The addressing format command is used for operating multiple monitor sets from a single PC via the RS232C command line..

Baud rate

Select Baud rate using the 5or 6button.. To set transmission speed RS232 or LD-NET communication for 19200 or 9600 Baud rate by pressing the 1or 2button..

Panel protection

To prevent image sticking which may occur showing still picture for a long time, select “Panel Protect” using the 5or 6button, once highlighted you can select ON or OFF by pressing the 1or 2

button..

AV Auto shut off

This LCD monitor allows you to set up the following:

SETTING PROCEDURE

1.Press and hold the GREEN button on the remote control for 5 seconds.. (Installation Mode will appear)

2.Use the 5or 6button to highlight each option, use the 1or 2button to adjust each option.. Press the MENU button to exit the mode..

On Program

Select ON program using the 5or 6button, select the start up position using the 1or 2buttons.. (Off/AV1/RGB/AV2/AV3/PC/DVI or Network)

Max Volume

Select Max volume using the 5or 6button, use the 1or 2 buttons to set the maximum volume required..

Winter mode

This Function can be activated when the LCD monitor is used dur- ing cold temperature conditions, approximately 38˚F/4˚C or below to maintain picture performance..

Using the 5or 6button select winter mode, once highlighted you can select ON or OFF by pressing the 1or 2button.. IMPORTANT: The AC cord should not be disconnected during the operation of Winter mode function..

When in winter mode, power consumption is higher than normal standby consumption.. This is entirely due to the operation of heating circuitry.. We strongly recommend to turn off Winter mode when the ambient temperature is above 38˚F/4˚C.

RC inhibition

You can prevent unwanted remote control operation by selecting RC Inhibition..

Select using the 5or 6button.. Press the 1or 2button to select On or Off..

To re-instate RC operation press and hold the green button on the remote control and select RC inhibition OFF..

Child Lock

You can prevent unwanted operation of the LCD monitor via the buttons on the rear of the monitor..

Select using the 5or 6button.. Press the 1button to select On or OFF. The “Child Lock” OSD will appear if buttons are pressed when child lock is On.

Standby operates normally when childlock is set “On”.

With no picture input signal to AV1, RGB, AV2(YPbPr), AV3, DVI, Network, set turns off automatically. Select “AV Auto Shut Off” using the 5or 6button, once highlighted you can select On or Off by pressing the 1or 2button..

Network Standby

You can save power consumption selecting “Off” at Network Standby in Installation mode, RS232C do not functional. To make them func- tional, select “ON” in this menu.

On Timer Function

You can save power consumption selecting “Off” at On Timer function in Installation mode.. On Timer in Time menu does not functional.. To make them functional, select “ON” in this menu.

LED Light setting

Select LED Light setting using the 5or 6button, once highlight- ed you can select On or Off by pressing the 1or 2button..

DCR

The picture contrast improved while DCR is ON.. Select DCR using the 5or 6button, once highlighted you can select On or Off by pressing the 1or 2button..

Network Initial

This function is not used..

Temperature Error

The recorded number of abnormal temperature is occurred is indi- cated here..

IP Address/Subnet/Gateway/DNS

This function is not used..

13

Image 13
Contents PID-42AE1 Table of Contents Installation and Use Safety PrecautionsImportant UK only Additional for North America and CanadaServicing ServicingImportant recycling information Please help us to conserve the environment we liveFederal Communications Commission Notice Servicing GBCanadian Radio Interference Regulations End-User License AC Power Cord RequirementGB Servicing Installation NoticeMains Connection InstallationConnections Input selectionRemote control battery installation Installation GBSwitching into/from standby mode GB InstallationControls and Menus Menu Operation Picture menuMenu Operation Setup menuSound menu Time menuPC Adj. menu GB Menu OperationInstallation Mode Installation ModeSetting Procedure DCRSelection of picture size OperationPIP2 mode PIP1 modeOFF mode POP mode Operation GBTeletext Operation Operation in Text ModeTXT/TV Specification SPECIFICATIONS/HELPFUL HintsHelpful hints Unit mm DimensionsPC signal support timing GB PC/DVI-D/COMPONENT Signal Support Timing List GBComponent signal support timing DVI-D signal support timingRS232C Command Tables RS232C Command Tables GB N8FA/N8FD-A
Related manuals
Manual 22 pages 60.23 Kb

PID-42AE1, PID-42AS1 specifications

The Sanyo PID-42AS1 and PID-42AE1 represent a significant advance in the world of air conditioning technology. Designed to offer exceptional performance, energy efficiency, and user comfort, these models are ideal for both residential and commercial applications.

Both models feature Sanyo's advanced inverter technology, which allows for precise temperature control and energy savings. By adjusting the compressor speed according to the current cooling needs, these units maintain a consistent temperature while reducing energy consumption. Inverter technology not only enhances efficiency but also minimizes noise levels, making these units suitable for quiet environments such as bedrooms and offices.

The PID-42AS1 is recognized for its superior cooling capacity. It features a powerful compressor that delivers rapid cooling, thus ensuring a comfortable indoor environment even during the hottest days. The unit also includes a high-efficiency air filter, which captures dust and allergens, promoting cleaner air circulation throughout the space.

On the other hand, the PID-42AE1 is designed with an eco-friendly approach. It utilizes R410A refrigerant, which has a lower impact on the environment compared to traditional refrigerants. Additionally, this model is equipped with energy-saving modes that allow users to optimize the cooling performance based on their needs, further enhancing its sustainability profile.

Both models boast an intuitive remote control that simplifies operation. With features like programmable timers and multiple cooling modes, users can easily customize their experience. The sleek design of these units allows them to blend seamlessly into any interior space, while the compact dimensions make them easy to install.

In summary, the Sanyo PID-42AS1 and PID-42AE1 offer a blend of innovative technology and user-friendly features. The inverter technology provides energy efficiency and noise reduction, while the advanced cooling capabilities ensure comfort. With eco-friendly refrigerant and filters that improve air quality, these models are at the forefront of modern air conditioning solutions. Whether for home or office use, Sanyo's commitment to quality and innovation is evident in every aspect of these air conditioning units.