Bogen CSUB specifications Suspended Ceilings

Page 6
Mounting clamps (×4)
2×2 CeilingTile

Installation (cont.)

SUSPENDED CEILINGS:

1. Remove the ceiling tile from the ceiling grid. Cut a 14-1/4" circular hole in the ceil- ing tile. Use the included template as a guide.

2.Put the CSUB face down on a workbench or on the floor without grille installed.

3.Place the ceiling tile over the CSUB, making

sure the ceiling tile is facing out. It is impor- tant to note the direction of the clamps: they must be installed so that they span the distance from one side of the ceiling tile to the other (approx. 24", see illustration at right). The front of the CSUB is engraved with guide arrows for “24- Inch Ceiling Tile” (see Product Diagrams section). Use these guides for this installation.

4. Using an electric powered screwdriver with the

 

 

 

clutch at a low setting, tighten each screw

 

 

 

until the clamps are just snug against the

 

 

 

Support rail Mounting clamps extend

tile surface. The CSUB’s clamps can be

 

to, but do not overhang,

tightened from either the front or rear of

 

edge of ceiling tile.

the speaker. Use a No. 3 Phillips screwdriv-

 

 

 

er when working from the front. Use a 1/4" flat-blade screwdriver when work- ing from the rear. If working from the rear of the speaker, the screws tighten COUNTERCLOCKWISE. Do not over-tighten clamps. Once all four clamps are properly positioned and snug on the ceiling tile, the assembly (CSUB and ceiling tile) is ready to be mounted in the ceiling grid.

5.Before installing the grille, make sure you have selected the proper power setting on the front panel rotary switch. Refer to the Selecting Power Levels section for instructions on selecting the power level. Install the grille as indicated in the Speaker Grille Installation & Removal section.

6.Before mounting the CSUB/tile assembly, make sure the snap-lock input connector has been connected to the input wires (see Speaker Wiring section). The CSUB/tile assembly may now be placed in the ceiling grid. By accessing the ceil- ing space through an adjacent ceiling tile, plug in the snap-lock connector.Attach the Terminal Cover using the screws provided. If using conduit, refer to the Terminal Cover section of this manual.

7.Attach the CK10 Safety Cable, if it is being used, by screwing the eyebolt into the safety tether point in the rear of the CSUB’s metal enclosure (see Product Diagrams).This may be a local code requirement. It is certainly a very good safe- ty measure, particularly in suspended ceiling installations. For more information see the instruction sheet included with the CK10.

6

Image 6
Contents Ceiling Subwoofer Model Csub Important Safety Instructions Product DescriptionProduct Diagrams Side DrawingRear Drawing Speaker Placement Installation Suspended Ceilings Drywall or Other Hard Surfaces Speaker Polarity Speaker WiringDaisy-Chaining Terminal CoverSelecting Power Levels Speaker Grille Installation & RemovalSpecifications AccessoriesLimited Warranty Exclusion of Certain Damages Spring Street, Ramsey, NJ 07446, U.S.A

CSUB specifications

Bogen CSUB is an advanced commercial sound system designed to provide high-quality audio solutions for a variety of applications. This system is particularly well-suited for educational institutions, corporate environments, retail spaces, and public address systems. Its main features, technologies, and characteristics make it a reliable choice for anyone looking to enhance their audio experience.

At the core of the Bogen CSUB system is its powerful yet compact design, which allows for easy integration into existing sound infrastructures without occupying substantial space. The system is engineered with versatility in mind, capable of supporting numerous speaker configurations. This ensures optimal sound coverage and clarity in different environments, from small classrooms to large auditoriums.

One notable feature of the Bogen CSUB is its advanced digital processing capabilities. The system employs state-of-the-art DSP (Digital Signal Processing) technology, which allows for precise tuning and equalization of audio output. This technology ensures that sound reproduction is accurate, providing a clear and balanced audio experience. Additionally, users can fine-tune settings to suit specific acoustical conditions, making it a highly adaptable solution.

The Bogen CSUB also boasts a comprehensive connectivity suite, allowing it to interface with a variety of audio sources. Whether connecting via Bluetooth, RCA, or line-level inputs, the system is designed for seamless integration, facilitating easy setup and operation. This flexibility is crucial for environments where different audio sources may be used frequently.

Another key characteristic of the Bogen CSUB is its robust build quality. The system is constructed with durable materials that can withstand the rigors of daily use, ensuring long-lasting performance. Furthermore, it features a user-friendly interface, allowing operators to quickly and easily adjust settings as needed.

The Bogen CSUB is equipped with various safety and protection features, such as over-voltage and short-circuit protection, ensuring reliability and peace of mind during operation. This makes it an ideal choice for mission-critical applications where consistent performance is paramount.

In summary, the Bogen CSUB is a versatile and advanced sound system that combines exceptional audio quality, robust features, and flexible connectivity options. Its digital processing capabilities, durable design, and comprehensive safety features make it a top choice for anyone seeking an effective audio solution that caters to diverse requirements across various settings.