Focal DUAL MANAGER user manual Default values, System and error messages

Page 15

5. Hints and tips

5.4. Default values

Before Dual Manager has been executed for the first time and Presets have been defined by the user, the amplifier firmware uses default values for the various parameters, as listed below:

SECTION

PARAMETER

DEFAULT VALUE

Crossover

Slope,dB

12

 

Frequency, Hz (High Pass)

500

 

Frequency, Hz (Low Pass)

5000

 

Crossover type

Band-Pass

 

Filter type

Linkwitz-Riley

Q-Bass

 

 

Level, dB

6

 

Frequency, Hz

80

 

Q

1.0

Input Section

 

 

Channel

Left/Right

 

Input Selector

Optical

Output Section

 

 

Level,dB

0

Equalizer

 

 

Level,dB

0

 

Q

2.0

 

Type

Peak

Time Delay

 

 

ms

0

Global

 

 

Headroom (dB)

6

 

All On/Off buttons

Off

 

Inverted button

Off

 

File name

No Name

 

User mode

Restricted

 

 

 

5.5. System and error messages

Hereafter is a list of system and error messages, with their explanations or contexts.

• Loading stages on start-up screen

“Wait hardware.”

“Init hardware.”

“Create amplifier screen”, “Init amplifier screen”, “Read config file”,”First device automatic selection.”

Wait idle state in hardware.

Initialize hardware data.

Create visual data.

15

Image 15
Contents Français Installation Preparing the computer and installing the programSystem requirements Launching Dual Manager Load menu Save menu Preferences menu Foreword on presets Title bar and menusLoad menu Preferences menu Save menuCrossover Setting up the system main screenOverview Output channel selectorCrossover type Crossover slope and frequency Bass section Bass Input section Output section Time delay section Time delay Input sectionOutput section Band Equalizer Sound effectGraphic area Remote controller LED codes Hints and tipsSpecial edition keys System and error messages Default valuesSoftware error messages Hardware connection errors