Bogen TPU250 manual Wall Mounting, Rack Mounting

Page 5

Figure 2: Wall Mounting the Amplifier

SCREW #8 x 5/8" (M4 x 16 mm)

WITH TEFRON WASHER 1/8 x 5/16 (3 x 8 MM)

TYP 4 PCS

POWER

PEAK

LEVEL

 

APHEX

TREBLE

BASS

 

VOX

VOLUME

RINGER

MUTE

MUSIC

VOLUME

MUSIC

 

MIC

VOLUME

TEL

VOLUME

ALC

 

 

.........................

....................

POWER

PEAK

LEVEL

APHEX

 

TREBLE

BASS

 

 

VOX

 

VOLUME

RINGER

 

MUSIC

MUTE

VOLUME

MUSIC

 

 

MIC

VOLUME

TEL

VOLUME

 

 

 

ALC

 

 

.........................

....................

RACK

MOUNTING

SCREWS ARE

NOT SUPPLIED

 

Figure 3: Rack Mounting the Amplifier

Installation

 

Mounting

The amplifier is designed for wall mount applications but can also be mounted in a

 

standard 19" rack. The TPU250 amplifier weighs 31 lbs.

 

NOTE: The amplifier will produce heat during operation which will rise and may

 

cause problems for temperature-sensitive equipment mounted above it. Mount the

 

amplifier near the top of the backboard (for wall mounting) or rack (for rack

 

mounting) so that no other equipment will be above it. If this is not possible, then

 

allow at least 12" between the top of the amplifier and the bottom of any equipment

 

positioned above it. Also allow at least 6" between the bottom of the amplifier and

 

any equipment below it to allow for adequate air circulation.

Wall Mounting

To wall mount this unit, use the four 5/8” pan head screws with nylon washers

 

provided (see Figure 2). Insert the top two screws first leaving the heads protruding

 

about 1/4”. Lift the amplifier and place it over the 2 screws using the top keyhole

 

slots in the flanges at the sides of the amplifier. Allow the amplifier to rest on the 2

 

screws and then proceed to insert the bottom 2 screws into the lower keyhole slots.

 

With all the screws in place, tighten the screws to secure the amplifier.

 

NOTE: Backboard must be a minimum of 3/8” thick plywood and securely mounted

 

to the wall.

Rack Mounting

The amplifier was designed to mount directly to standard 19” racks using the

 

mounting flanges as shown in Figure 3 (rack screws are not supplied). In the factory

 

set position, the unit will protrude from the front of the rack.This provides the best

 

ventilation of the unit and easier access to the wiring connections.

 

NOTE: The unit can also be mounted partially recessed in the rack by reversing the

 

mounting flanges. Unscrew the mounting flanges (3 screws mount the flange to the

 

cover) and install them in a flipped over orientation. This position will provide

 

adequate ventilation and centers the weight of the unit over the rack rails.

Page 5 of 12

Image 5
Contents TPU250 Telephone Paging Amplifier Domestic and International Listings Important Safety InformationApplications Assistance Contents Introduction Package ContentsRack Mounting MountingWall Mounting Input Wiring Wiring ConnectionsConnect Microphone to Telephone Paging Amplifier Bogen MBS1000 Microphone CableBridging Inputs Speaker Connection, Output Wiring WMT1A Controls IndicatorsOperation