Panasonic TH-85PF12U Serial Terminals connection, Signal names for D-sub 9P connector, Command

Page 11

Connections

SERIAL Terminals connection

The SERIAL terminal is used when the Plasma Display is controlled by a computer.

COMPUTER

 

(Male)

 

 

 

RS-232C Straight cable

SERIAL

 

 

1 2 3 4 5

6 7 8 9

Pin layout for SERIAL Terminal

(Female)

D-sub 9p

Notes:

Use the RS-232C straight cable to connect the computer to the Plasma Display.

The computer shown is for example purposes only.

Additional equipment and cables shown are not supplied with this set.

The SERIAL terminal conforms to the RS-232C interface specification, so that the Plasma Display can be controlled by a computer which is connected to this terminal.

The computer will require software which allows the sending and receiving of control data which satisfies the conditions given below. Use a computer application such as programming language software. Refer to the documentation for the computer application for details.

Signal names for D-sub 9P connector

Pin No.

Details

 

2

R X D

 

3

T X D

 

5

GND

4

6

Non use

 

7

(Shorted in this set)

 

8

 

 

1

9

NC

These signal names are those of computer specifications.

Communication parameters

Signal level

RS-232C compliant

Synchronization method

Asynchronous

Baud rate

9600 bps

Parity

None

Character length

8 bits

Stop bit

1 bit

Flow control

-

Basic format for control data

The transmission of control data from the computer starts with a STX signal, followed by the command, the parameters, and lastly an ETX signal in that order. If there are no parameters, then the parameter signal does not need to be sent.

STX C1 C2 C3 : P1 P2 P3 P4 P5 ETX

 

Colon

Parameter(s)

End

Start

3-character

(1 - 5 bytes)

(03h)

(02h)

command (3 bytes)

 

 

Notes:

If multiple commands are transmitted, be sure to wait for the response for the first command to come from this unit before sending the next command.

If an incorrect command is sent by mistake, this unit will send an “ER401” command back to the computer.

SL1A, SL1B, SL2Aand SL2B of Command IMS are available only when a dual input terminal board is attached.

Command

Command

Parameter

Control details

PON

None

Power ON

POF

None

Power OFF

AVL

**

Volume 00 - 63

AMT

0

Audio MUTE OFF

 

1

Audio MUTE ON

IMS

None

Input select (toggle)

 

SL1

Slot1 input

 

SL2

Slot2 input

 

SL3

Slot3 input

 

PC1

PC input

 

SL1A

Slot1 input (INPUT1A)

 

SL1B

Slot1 input (INPUT1B)

 

SL2A

Slot2 input (INPUT2A)

 

SL2B

Slot2 input (INPUT2B)

DAM

None

Screen mode select (toggle)

 

ZOOM

ZOOM (For Video/SD/PC signal)

 

FULL

FULL

 

JUST

JUST (For Video/SD signal)

 

NORM

4:3 (For Video/SD/PC signal)

 

SELF

Panasonic Auto (For Video signal)

 

SJST

JUST (For HD signal)

 

SNOM

4:3 (For HD signal)

 

SFUL

H-FILL (For HD signal)

 

ZOM2

ZOOM (For HD signal)

With the power off, this display responds to PON command only.

11

Image 11
Contents English High Definition Plasma DisplayOperating Instructions Risk of Electric Shock Do not Open Important Safety Instructions Table of Contents Trademark Credits FCC CautionCanadian Notice When using the Plasma Display Safety PrecautionsAC Power Supply Cord MaintenanceSafety Precautions / Maintenance SetupRemote Control Batteries AccessoriesAccessories Supplied Audio OUT Terminals connection ConnectionsConnections Signal Names for Mini D-sub 15P ConnectorPC Input Terminals connection Communication parameters Signal names for D-sub 9P connectorCommand Serial Terminals connectionDVD Hdmi connectionComponent / RGB connection RCA-BNCRight side surface Power on / OFFConnecting the plug to the Wall Outlet OSD Language Power on / OFFWhen first switching on the unit Present Time SetupINPUT1 INPUT2A INPUT2B INPUT3 PC Selecting the input signalBasic Controls On OFF Basic ControlsPanasonic Auto All Aspect modeAspect Controls During Advanced PIP Selecting the Display ModeAspect Controls During PIPTransparent Function Insertion Function Swapping ScreensDuring Blend PIP Composite Screen Function Transparent Function and Insertion FunctionOperations on Main screen Sub screen Selecting the Target Screen for OperationsSelecting the Sub Screen Position During P in P Display Select the magnification required for the enlarged display Digital ZoomDisplay the operation guide Select the area of the image to be enlargedSet Remote Control Unit Display the menu screenOn-Screen Menu Displays Select the itemOverview On-Screen Menu DisplaysAuto mode Adjusting POS. /SIZEUsing Remote Control Adjusting POS. /SIZE OFF On Left On Center On Right 2k1kCinema Picture AdjustmentsStandard DynamicPicture Adjustments Advanced SettingsMY Picture MEMORY1 Picture ProfilesPicture Profiles Saving profilesRenaming profiles Loading profilesEditing profiles Deleting profiles NoteMemory Save Locking profilesMemory Edit Isf Mode Off Isf Mode On Changing passwordsIsf Mode Setting Picture Menu mode displaySDI Sound Output Sound AdjustmentPower OFF Time Present Time SetupSET UP Timer Function selection Mode selectionStart setting Screensaver For preventing image retentionScreensaver For preventing image retention Setup of Screensaver TimeImage Retention Reduction Menu Extended Life SettingsSide BAR Adjust Reduces screen image retentionNanodrift Saver Extended Life Settings when profile is lockedReset Reduces screen image retentionCustom Settings Reduces power consumption Addition sign Selected Input Customizing the Input labelsSelecting the On-Screen Menu Language SLOT3Landscape Portrait Display OrientationDisplay Number locations for each arrangement Examples SET UP for Multi DisplayHow to setup Multi Display ID Cancellation ID Remote Control FunctionSET UP for Multi Display ID remote control button operationInsert Level Transparent Display of the Sub Screen During Blend PIPSub Screen Insertion During Blend PIP PIP Advanced PIP Blend PIPMulti SET UP for PortraitHow to setup Portrait Viewing Area Location SET UP for PortraitLocation Viewing Area and LocationComponent RGB SET UP for Input SignalsComponent / RGB in Select YUV / RGB in Select3D Y/C Filter For Ntsc AV images Signal menuSET UP for Input Signals Color System XGA ModeColor System / Panasonic Auto PulldownVideo NR, Mosquito NR, Block NR Refresh RateNoise Reduction Advanced NRSDI Through Input signal displaySetting RGB sync signal SyncOptions Options AdjustmentsButton lock Options AdjustmentsNormalization DelayPress Action Button Weekly Command TimerShipping condition Plasma Display panel TroubleshootingFull List of Aspect ModesComponent / RGB DVI-D in ∗8 Applicable Input SignalsVGA60 Applicable Input SignalsVideo input Hdmi Asos Command list of Weekly Command TimerScreen size SpecificationsFor the U.S.A and Puerto Rico Panasonic Professional Flat Panel Display Limited WarrantyFor Canada Limited Warranty StatementPage Memo Memo Memo Panasonic Canada Inc Customer’s RecordPanasonic Professional Display Company Executive Office
Related manuals
Manual 72 pages 32.18 Kb