Page 3 of 8 |
GENERAL DESCRIPTION
The SA500 Siren Amplifier is a premium unit designed for single or dual 100W speaker use. The primary operating modes are Yelp, Wail, Standby and Radio. A Noise Canceling PA Override and
| SPECIFICATIONS |
|
| ||
|
|
|
|
| |
Input Voltage | 9 - 16 VDC (negative ground) |
|
|
| |
Input Current | 8 AMPS (@14 VDC - single 100W speaker) |
|
| ||
| 16 AMPS (@14 VDC - dual 100W speakers) |
|
| ||
Standby Current | Less than 150 ma |
|
|
|
|
Audio Frequency | 200Hz - 10 kHz + 3db |
|
|
| |
Audio Distortion | Less than 3% (@1 kHz - single 100W speaker) |
|
| ||
Audio Output | 40 watts (@14 VDC - single 100W speaker) |
|
| ||
Audio Input | 400 ohms + 10% |
|
|
|
|
Output Power | 105 WATTS RMS MAX. (15 VDC - single 100W speaker) |
| |||
| 180 WATTS RMS MAX. (15 VDC - dual 100W speakers) |
| |||
Siren Frequency | 700Hz - 1500Hz |
| |||
Tones/Cycle Rates | Horn | Wail | Yelp | Phaser | |
| 109 CPS | 13 CPM | 190 CPM | 15 CPS | 60 CPM |
High Voltage Protection | 16 - 18 VDC will cause siren output to cease, resume at normal |
| |||
Short Circuit Current | 50 AMPS (supply circuit must be capable of supplying this) |
| |||
Operating Temp. |
|
|
|
| |
Controls |
| ||||
| Momentary |
|
| ||
| Momentary |
| |||
| Front panel PA and Radio volume controls. |
|
| ||
| Auxiliary input connection programmable for positive or negative activation. | ||||
| Cutout input connection programmable for positive or negative latching operation. | ||||
| Internal |
|
| ||
Connections | (2) Positive, (2) Negative, (2) Speaker, (2) Radio, Cutout, Auxiliary |
| |||
Size |
|
| |||
Weight |
|
|
|
|
INSTALLATION
Proper installation of the unit is essential for years of safe, reliable operation. Please read all instruction before installing the unit. Failure to follow these instructions can cause serious dam- age to the unit or vehicle and may void warranties.
SAFETY PRECAUTIONS
For the safety of the installer, vehicle operator, passengers and the community please observe the following safety precautions. Failure to follow all safety precautions and instructions may result in property damage, injury or death.
Qualifications - The installer must have a firm knowledge of basic electricity, vehicle electrical systems and emergency equipment.
Sound Hazard - Sound level from siren speaker (>120dBA @ 10 feet) may cause hearing damage. Do not operate siren without adequate hearing protection for you and anyone in immediate vicinity. (Ref. OSHA 1910.95 for occupational noise exposure guidelines)
Mounting - Mount the unit for easy access by the vehicle operator. DO NOT mount in air bag deployment area. Assure clearances before drilling in vehicle. To prevent internal damage mounting bolts must not enter case more than 1/4".
CP4874B | 05/07/05 |