Carson SA-500-11 14V manual INSTALLER-SELECTABLE Options

Page 4

INSTALLER-SELECTABLE OPTIONS

Carefully cutting programming resistor jumpers or traces on the printed circuit board inside the case can select various options. The cover must be removed to access the jumpers. The cover is held in place by a snap-fastener on the back of the unit. Hold the unit with the front case flange on the edge of a hard surface and press hard on the back of the unit. The chassis will slide out the front of the cover.

Auxiliary Input Function - The auxiliary input normally activates the Horn function. Do not cut the jumper resistor labeled "AUX I".

FUSE

AUX P

CUT P

T-T AUX I PHSR

 

 

 

OPTION JUMPERS

Auxiliary Input Polarity - The auxiliary input is normally activated by connecting to positive. To activate by connecting to ground cut the two jumper resistors labeled "AUX P".

Cutout Input Polarity - The cutout input is normally activated by connecting to positive. To activate by connecting to ground cut the two jumper resistors labeled "CUT P".

Two-Tone- Not available, do not cut the jumper resistor labeled "T-T".

Phaser Disable - The Phaser function is disabled, do not cut the jumper resistor labeled "PHSR".

Horn Disable - The Horn function can b e disabled by cutting the trace on the back of the board at the location designated "cut to disable horn".

Cut to Disable horn

TB0354A

Page 4 of 8