Dynacord DPA 4140, DPA 4120 owner manual NRS 90 406 S

Page 14

When off-ground potential loudspeaker cable networks are employed we recommend insulation-monitoring using the ground fault surveillance module NRS 90224. Error recognition: An occurring ground fault either signals that one of the cables is damaged - which most likely point towards a total line interruption in the near future - or that connections have been carried out erroneously which may lead to malfunctioning of the entire system. The fault message GROUND FAULT (6) is also maintained with very short (>5 sec) ground faults, as long as the amplifier is powered-on or a loaded battery is connected. The fault message is displayed via the red GROUND FAULT indicator (6). In case of an inserted INPUT MODULE NRS 90225, it is also outputted as collective fault message with the floating contact of the READY fault message relay via the REMOTE CONTROL connector (16). When using the REMOTE MODULE NRS 90222, error occurrence is monitored and output by the PROMATRIX manager DPM 4000 (for further details, please refer to the PROMATRIX handbook).

The installation has to be performed as follows (see figure 8 and/or figure 9):

Caution Before opening the appliance, make sure to disconnect the mains and/or battery power source!

-To open the appliance, the top panel has to be removed.

-The extension kit NRS 90224 has to be inserted with its component side to the left (from the front view) until it clicks in place.

-Re-install the top plate of the enclosure.

NRS 90 224

S406 S 405

36

Image 14
Contents Power Amplifier DPA 4120 / DPA Performance FeaturesPage Indicators, controls and connections 12 aContents Amplifier has to be protected from InstallationUtilization Before the first operationBattery operation 24V DC InputPower Output for 100V 70V or 50V loudspeaker systems OutputsIndicators Power Output for low impedance loudspeaker systemsRemote Control connector only NRS Single Call and obligatory reception relays Override BypassProtect indicator Standby indicatorReady indicator Ground Fault indicatorEnhanced application field Standard input module NRS Remote module NRS NRS 90208 input transformer for the floating, balanced inputRe-insert the input module and tighten the locking screws B Pilot tone surveillance NRS 90224 pilot tone & ground fault surveillanceGround fault surveillance NRS 90 406 S 411 Checking the pilot tone surveillance function Ground lift switch Circuit ⊥ to Chassis Switch Checking the ground fault surveillance functionCase and 19-rack-shelf system installation Fuses Fuses in the DPA503 502 503 F 601 602 Battery operation DPA 4140 power amplifier 400 W Power supply NRS 90208 input transformer for floating, balanced input 13.5.2 Ground fault surveillanceExtension kits for the DPA 4120 and DPA
Related manuals
Manual 72 pages 6.17 Kb

DPA 4120, DPA 4140 specifications

The Dynacord DPA 4120 and DPA 4140 are powerful amplifier solutions designed for professional audio applications. These models are ideal for live sound reinforcement, permanent installations, and various audio distribution requirements.

Both DPA 4120 and DPA 4140 are part of the Dynacord DPA series, which is renowned for delivering high-quality sound and reliability in demanding environments. The DPA 4120 provides a robust 1200 watts of power per channel at 4 ohms, while the DPA 4140 ups the ante with an impressive 1400 watts per channel at the same impedance, making them suitable for driving a wide range of speaker systems.

One of the standout features of both amplifiers is the incorporation of advanced DSP (Digital Signal Processing) technology. This technology offers precise control over sound performance, allowing users to tailor settings to meet specific venue acoustics or personal preferences. The DSP includes functions such as equalization, crossover adjustments, delay, and limiting, ensuring optimal sound delivery in any setting.

Durability is another hallmark of the Dynacord DPA series. The amplifiers feature a rugged, lightweight design, ideally suited for touring and rental companies. The internal architecture includes a sophisticated cooling system that allows for extended operation under high-demand conditions without overheating.

Both models are equipped with a range of connectivity options, including XLR inputs and Speakon outputs, facilitating seamless integration with various audio systems. The amplifiers support both analog and digital input sources, ensuring compatibility with modern audio setups.

In terms of sound quality, the DPA 4120 and DPA 4140 are engineered with low distortion levels and high efficiency, achieving high-performance audio output while maintaining clarity and detail across all frequencies. The amplifiers also feature a robust power supply that delivers consistent performance, even during peak use scenarios.

User-friendly controls and monitoring options are also inherent in the design of these amplifiers. An intuitive front panel interface allows for easy adjustment of settings, while LED indicators provide real-time feedback on performance and operational status.

In summary, the Dynacord DPA 4120 and DPA 4140 offer exceptional power, sound quality, and advanced features, making them excellent choices for audio professionals seeking reliable and powerful amplification solutions. Their combination of performance, durability, and versatility serves to meet the needs of various professional audio applications, solidifying their place in the competitive landscape of audio amplifiers.