Triax 120, UFO 100 manual Troubleshooting guide, Problem Possible root cause Solution

Page 5

GB

Troubleshooting guide

Problem

Possible root cause

Solution

 

 

 

Weak or missing signal

NO light indicates no voltage.

Remove the cable from the

-check LED on power supply

Often this is coursed by a short

PSU, if the LED goes ON,

(PSU)

or a missing connection in the

there is a short in the cable.

 

coax-cable or the cable con-

Then repair or replace the

 

nectors

cable.

 

 

If the LED is still off replace

 

 

the PSU.

 

 

 

Weak or missing signal

NO light indicates no voltage.

If the LED is ON at the PSU,

-check LED on power supply

Often this is coursed by a short

there is probably a missing

(PSU)

or a missing connection in the

connection in the cable or

-check LED on UFO

coax-cable or the cable con-

connectors.

 

nectors

Repair or replace.

 

 

 

Interference; herring-bone pat-

Interference is often caused by

Increase the distance – in-

tern or white horizontal stripes

different electronic equipment

crease the height of the UFO

in the picture.

- mobile phones, computers

 

 

or transmitters -being used in

 

 

close proximity to the UFO.

 

 

 

 

Ghosting; double pictures

Ghosting is caused by the TV

Changing position a few

 

signal being reflected from

meters, will often solve the

 

buildings, large ships etc.

problem.

 

 

 

5

Image 5
Contents UFO 100 UFO 100 Mounting options on vertical or horizontal surface Mounting with universal mount UFO 120 digital Mounting with centre mount UFO 120 digitalProblem Possible root cause Solution Troubleshooting guideApplication examples Accessories Technical data891020A 06-2009