Planar PL1910MW manual Troubleshooting, Problem Picture is unclear and unstable

Page 16

Troubleshooting

This LCD Monitor has pre-adjusted using factory standard VGA timings. Due to the output timing differences among various VGA cards in the market, users may initially experience an unstable or unclear display whenever a new display mode or new VGA card is selected.

Attention

This LCD Monitor Supports Multiple VGA Modes.

Refer to the Standard Timing Table for a listing of modes supported by this LCD Monitor.

PROBLEM Picture is unclear and unstable

The picture is unclear and unstable, please perform the following steps:

1.Enter PC to “Shut Down Windows” status while you’re in MS-Windows environment.

2.Check the screen to see if there’s any black vertical stripes appear. If there are, take advantage of the “Clock” function in OSD menu and adjust (by increment or decrement numbers) until those bars disappear.

3.Move to “Phase” function in OSD menu again and adjust the monitor screen to its most clear display.

4.Click “No” on “Shut Down Windows” and back to the normal PC operating environment.

PROBLEM There is no picture on LCD Monitor

If there’s no picture on the LCD Monitor, please perform the following steps:

1.Make sure the power indicator on the LCD Monitor is ON, all connections are secured, and the system is running on the correct timing. Refer to Chapter 3 for information on timing.

2.Turn off the LCD Monitor and then turn it back on again. If there is still no picture, press the Adjustment Control button several times.

3.If step 2 doesn’t work, connect your PC system to another external CRT. If your PC system Functions properly with a CRT Monitor but it does not function with the LCD Monitor, the output timing of the VGA card may be out of the LCD’s synchronous range. Please change to an alternative mode listed in the Standard Timing Table or replace the VGA card, and then repeat steps 1 and 2.

PROBLEM There is no picture on LCD Monitor

If you have chosen an output timing that is outside of the LCD Monitor’s synchronous range (Horizontal: 30 ~

80 kHz and Vertical: 56 ~ 75 Hz), the OSD will display a “Out of Range” message. Choose a mode that is supported by your LCD Monitor.

Also, if the signal cable is not connected to LCD monitor at all or properly, the monitor screen will display a message “No Input Signal”.

15

Image 16
Contents Page Contents Preface FCC Statement WarningImportant Safety Instructions Installation UnpackingConnecting the LCD Monitor and Base Viewing Angle AdjustmentConnecting the Display Detaching LCD Monitor from Its StandConnecting the AC Power Connecting the Audio CableSetting Up the LCD Monitor Power Management SystemDisplay Controls User ControlsMenu/Enter Auto/ExitSub Adjusting the Monitors DisplayDescription Full AspectOSD SUB9300 75005000 UserSpecifications Technical InformationPower Management TmdsStandard Timing Table Sync TOTAL/ Active Front Back Pixel Timing Name Troubleshooting Problem Picture is unclear and unstableCables, Replacement Lamps, Accessories Technical Support Product Registration and Technical SupportRegister Your Planar Products Today Planar Support