XM-SD22X
SECTION 3
ELECTRICAL ADJUSTMENT
Bias Adjustment
Note : In Bias Adjustment, adjust RV103 if any of Q108 through
Q113 are replaced. Adjust RV203 if any of Q208 through
Q213 are replaced.
Condition : This adjustment should be performed about one minute after the remote mode is turned on at a room tempera- ture of about 25°C.
Setting :
B+, REM terminal
set
Stabilized
Power supply
GND terminal
Procedure :
1.Turn the variable resistors RV103
2.The input signal is to be no signal.
3.Apply the voltage to the B+ and REM terminals from the stabi- lized power supply and gradually increase it up to 12.0 V while checking for any unusual current.
4.Adjust each of RV103
5.After adjustment, check that the power current is at 1.65 to 2.05 A.
Adjustment Location : Main board (component side)
— MAIN BOARD (CONDUCTOR SIDE) —
RV103 | RV203 |
BIAS ADJUSTMENT | BIAS ADJUSTMENT |
10