SECTION 4
MECHANICAL ADJUSTMENTS
1.Clean the following parts with a
playback head | pinch roller |
rubber belt | capstan |
idles |
|
2.Demagnetize the playback head with a head demagnetizer.
3.Do not use a magnetized screwdriver for the adjustments.
4.After the adjustments, apply suitable locking compound to the parts adjusted.
5.The adjustments should be performed with the power supply voltage unless otherwise noted.
•Torque Measurement
Mode | Torqu Meter | Meter Reading | |
|
|
| |
Forward | 30 - 65 g·cm | ||
(0.42 - 0.90 oz·inch) | |||
|
| ||
Forward | 0.5 - 4.5g·cm | ||
Back Tension | (0.01 - 0.06 oz·inch) | ||
| |||
|
|
| |
Reverse | 30 - 65 g·cm | ||
(0.42 - 0.90 oz·inch) | |||
|
| ||
|
|
| |
Reverse | 0.5 - 4.5g·cm | ||
Back Tension | (0.01 - 0.06 oz·inch) | ||
| |||
|
|
| |
FF, REW | 60 - 200 g·cm | ||
(0.83 - 2.78 oz·inch) | |||
|
| ||
|
|
| |
• Tape Tension Measurement |
| ||
|
|
| |
Mode | Torqu Meter | Meter Reading | |
|
|
| |
Forward | more than 90 g | ||
(more than 3.18 oz) | |||
|
| ||
Reverse | more than 90 g | ||
(more than 3.18 oz) | |||
|
|
SECTION 5
ELECTRICAL ADJUSTMENTS
TEST MODE
This set have the test mode function. In the test mode, FM Auto Scan/Stop Level and AM (MW) Auto Scan/Stop Level adjustments can be performed easier than it in ordinary procedure.
<Set the Test Mode>
1.Set the “OFF” mode.
2.Push the preset 4 button.
3.Push the preset 5 button.
4.Press the preset 1 button for more than two seconds.
5.Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the “OFF” button.