7-8.  IC PIN FUNCTION DESCRIPTION
•MAIN BOARD IC302 CXP84124-078Q  (SYSTEM CONTROLLER)
| Pin No. | 
 | Pin Name | I/O | 
 | 
 | 
 | 
 | Function | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 1 | 
 | LIM.SW | I | Sled limit in detect switch (SW1) input terminal | 
 | ||||||
| 
 | “L”: When the optical  | 
 | 
 | ||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 2 | 
 | BUSON | I | Bus on/off control signal input from the SONY bus interface (IC204) | “H”: bus on | ||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 3 | 
 | EJECT | I | Eject switch (SW303) input terminal | “H” active | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 4 | 
 | LOAD1 | I | Save end detect switch (SW12) input terminal | 
 | 
 | |||||
| 
 | “L”: When completion of the disc chucking operation | 
 | |||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 5 | 
 | LOAD2 | I | Chucking end detect switch (SW11) input terminal | 
 | ||||||
| 
 | “L”: When completion of the disc chucking operation | 
 | |||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 
 | 
 | 
 | 
 | 
 | |||||||
| 6 | 
 | A.MUTE | O | Audio line muting on/off control signal output terminal “H”: muting on | |||||||
| 
 | 
 | 
 | 
 | 
 | |||||||
| 7 | 
 | EMPH | O | Emphasis mode output to the D/A converter (IC401) “L”: emphasis on | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 8 | 
 | CH.R | O | Motor drive signal (save direction) output to the chucking motor drive (IC52) | |||||||
| 
 | “H” active | *1 | 
 | 
 | 
 | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 9 | 
 | CH.F | O | Motor drive signal (load chucking direction) output to the chucking motor drive (IC52) | |||||||
| 
 | “H” active | *1 | 
 | 
 | 
 | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 10 | 
 | 
 | — | O | Not used (open) | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 11 | 
 | ELV.R | O | Motor drive signal (elevator down direction) output to the elevator motor drive (IC301) | |||||||
| 
 | “L” active | 
 | *2 | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 12 | 
 | ELV.ON | O | Mechanism deck section power supply on/off control signal output | “H”: power on | ||||||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 13 | 
 | CD RST | O | System reset signal output to the CXA1992AR (IC11), CXD2530Q (IC101) and SM5852FS | |||||||
| 
 | (IC102) | “L”: reset | 
 | 
 | 
 | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 14 | 
 | CDON | O | D/A converter and servo section power supply on/off control signal output “H”: power on | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 15 to 23 | 
 | 
 | — | O | Not used (open) | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 24 | 
 | AUTO ON/OFF | I | Setting terminal for the automatic adjustment | “L”: automatic adjustment, “H”: manual | ||||||
| 
 | adjustement (solder across the BP302 terminal) | Normally: fixed at “L” | |||||||||
| 
 | 
 | 
 | 
 | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 25 to 29 | 
 | 
 | — | O | Not used (open) | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 
 | 
 | 
 | 
 | 
 | System reset signal input from the reset signal generator (IC202) and SONY bus interface | ||||||
| 30 | 
 | RESET | I | (IC204) | “L”: reset | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H” | ||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 31 | 
 | EXTAL | I | Main system clock input terminal (8 MHz) | 
 | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 32 | 
 | XTAL | O | Main system clock output terminal (8 MHz) | 
 | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| 33 | 
 | VSS | — | Ground terminal | 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 34 | 
 | 
 | TX | O | Sub system clock output terminal | Not used (open) | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 35 | 
 | TEX | I | Sub system clock input terminal | Not used (fixed at “L”) | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 36 | 
 | AVSS | — | Ground terminal (for A/D converter) | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 37 | 
 | AVREF | I | Reference voltage (+5V) input terminal (for A/D converter) | 
 | ||||||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 38 | 
 | ATRIBT | I | Selection input of the custom file,  | 
 | ||||||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 39 | 
 | MCK | I | Input of signal for the fine adjustment (linear position sensor adjustment; RV301) of elevator | |||||||
| 
 | position (A/D input) | 
 | 
 | 
 | 
 | ||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | |||||||
| 40 | 
 | EHS | I | Elevator height position detect input from the RV302 (elevator height sensor) (A/D input) | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 41 | 
 | H.TEMP | I | High temperature sensor input terminal | Not used (open) | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 42 | 
 | 
 | — | O | Not used (open) | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 43 | 
 | MODE1 | O | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 44 | 
 | MODE2 | O | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 45 | 
 | MODE3 | O | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 46, 47 | 
 | 
 | — | O | Not used (open) | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | |||||||
| 48 | 
 | SCK | I | Serial data transfer clock signal input from the SONY bus interface (IC204) | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 49 | 
 | 
 | SI | I | Serial data input from the SONY bus interface (IC204) | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
– 34 –