Clock synchronization can be used as a handshaking mechanism, to enable receivers to cope with fast data transfers. On a byte level, a slave (host application-side) I2C device may be able receive a data transfer, but need time to store the byte received before it is ready to receive another byte. The slave/receiver will therefore hold the SCL line low, after sending the acknowledge bit following the byte received, thereby forcing the master into a wait state. Once the SCL is released by the slave/receiver, the wait state of the master will end. This feature of the I2C standard is known as clock-stretching and is supported by the GTR64.

The I2C interface supports Standard-mode (100kbps) and Fast-mode (400kbps). It also supports Normal (7-bit) addressing and Extended (10-bit) addressing

.

Parameter

Min

Typ

Max

Unit

SCL clock frequency

0

 

400

kHz

 

 

 

 

 

LOW period of the SCL clock

1.3

 

 

μs

HIGH period of the SCL clock

0.6

 

 

μs

 

 

 

 

 

Data hold time

0

 

0.9

μs

Capacitive load for each bus line

 

 

400

pF

3.7.3. SPI Bus

SPI: The implementation of SPI uses the same command structure as the AT command AT*E2SPI. The current implementation of this function only supports SPI Mode 0 (data is latched on a rising clock edge and the default state of the clock is low).

4 wires are used - CLOCK (IO1 pin), DATA INPUT (IO2 pin), DATA OUTPUT (IO3 pin), and SYNC (RI pin).

3.7.4. General Purpose IO

 

Pin

 

GTR64

 

Dir

 

Max. Voltage

 

Description

 

 

 

 

Signal

 

 

 

limits

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

IO 1

 

I/O

 

-0.5 - VREF

 

Digital Input/Output I/O 1

 

 

 

 

 

 

Digital VREF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

IO 2

 

I/O

 

-0.5 - VREF

 

Digital Input/Output I/O 2

 

 

 

 

 

 

Digital VREF

 

 

 

 

 

 

 

 

 

 

 

 

5

 

IO 3

 

I/O

 

-0.5 - VREF

 

Digital Input/Output I/O 3

 

 

 

 

 

 

Digital VREF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

IO 4

 

I/O

 

-0.5 - VREF

 

Digital Input/Output I/O 4

 

 

 

 

 

 

Digital VREF

 

 

 

 

 

 

 

 

 

 

 

 

10

 

RI1

 

O

 

0.4 – 3.2 V

 

Ring Indication

 

 

 

IO 8

 

I/O

 

-0.5 - VREF

 

Digital Input/Output I/O 8

 

 

 

 

 

 

 

 

GTR64 Integrators Manual V.1.2 Pag. 21

Preliminary. Subject to change without prior notice

Image 21
Contents GTR64 TerminalService and Support Important informationSecond EDITION. July GTR-64 Wireless modems in a Communication System Installation of the Modem Description IntroductionGeneral Features Radio FeaturesData Features HighlightsVoice Features GTR-64 Wireless modems in a Communication SystemShort Message Service SMS Features Internet ProtocolsMain Blocks in a Wireless System external micro-controller Short Message Service Main Features and ServicesTypes of Mobile Station GmskPower Consumption PrecautionsData Gprs Multi-Slot SupportOverview Mechanical DescriptionDimensions of the GTR64 terminal in mm DimensionsPower Conector Signal Dir Limits DescriptionElectrical Description Audio Conector Pin Signal Dir DescriptionElectrical characteristics are given in the table below Mini USB ConnectorAntenna Conector SIM card readerParameter Limit Description RS232 Serial Port Pin Signal Dir Voltage Description Levels Serial Data Signals RD, TD Control Signals RTS, CTS, DTR, DSR, DCD, RI Serial Data Dir Max. Voltage Description Signal Limits Expansion I/O portPin GTR64 RI1 ServiceADC Pin Name Direction FunctionParameter Min Typ Max Unit SPI BusGeneral Purpose IO Real Time Clock Software UpdatesSwitching Off the Modem Switching On the ModemResetting the Modem OperationEmbedded Applications FeaturesImplementation LimitationsSafety instructions Safety and Product CareGeneral precautions 2 M2mpower IDE Integrated Developers EnvironmentSIM card precautions Antenna precautionsRadio Frequency RF exposure and SAR Where to install the modem Installation of the ModemSignal strength Personal Medical DevicesAntenna How to install the modemAntenna placement AccessoriesAntenna type Antenna cableOpaniel Technologies Magnetic Dual Band Antenna 900/1800MHzRight angle short antenna Service GND SDA Vrtc Alarm VrefSCL RD3 TD3 RI1/IO8CBS CBMCSD DCEAT command Description AT Command SummaryGTR64 AT*E2CMGL AT*E2RESETAT*E2CMGR AT*E2EAMSPage AT+CHLD y AT+CSMP GTR64 AT+CSIMAT+CSMS AT+CSNS