500-19-54 Dual Channel Telephone Interface
6.
6.1Introduction
The
6.4
6.5
6.3
6.2IMP
6.2
6.2
6.3
This jumper allows matching of the line impedance to “CTR21”, to 600R or to a custom network by fitting components onto a
6.3Dial Tone / K-Break
In auto mode the line hold condition can be dropped automatically on detection of continuous dial tone for 6 seconds or by the detection of a break in the line current generated from the exchange, (called K break).
With the jumpers fitted these signals will be detected. In some uses the automatic clearing by one or both methods might be a problem and the required jumper can be removed to disable detection.
6.4Reset Switch
You can return the card to Factory Default by pressing and holding the button for about 6 seconds. It will give 10 slow flashes and then speed up. When it speeds up let go and it will be reset.
6.5Programmable Port This is for factory use only.
The Trilogy Dual Hybrid frame should only be connected to a Line via an appropriate approved fuse disconnection barrier.