Hubbell manual UH24 Universal Hose REEL-DIRECT Drive, Installation, Maintenance

Page 1
BROKEN SPRING
INDICATORS
“OUT” with 2/3 cable off reel–
SPRING BROKEN
Figure 3
“IN” with 2/3 cable off reel–
SPRING OK

INSTALLATION and MAINTENANCE INSTRUCTIONS

UH24 UNIVERSAL HOSE REEL-DIRECT DRIVE

NOTE: These instructions are written for machine pull reels.

If installing or servicing hand pull reel, use only those steps marked with hand .

All units are provided with right hand rotation unless otherwise specified. This means that hose is pulled off spool top left or bottom right (spool rotates clockwise to wind hose) when

viewing spring end of reel. See diagram on parts page.

Clock-type springs provide power for automatic hose take-up.

Spring must be pretensioned at time of installation to

insure that tension is applied to hose at all times. A tension adjustment spanner wrench is provided with each reel.

INSTALLATION

WARNING

If machine pull reel, move machinery to position closest

to reel before adjusting spring tension. Adjusting tension with hose extended may result in

damage to reel or personal injury.

1. Install hose if reel was purchased without hose. See instructions on page 4.

2. Insure that machinery to be serviced by reel is at position closest to reel.

3. Securely mount reel in desired position using 1/2"(M12). Be sure spool is aligned with hose run.

4. Position hose guide if supplied so hose pays-out as straight as possible through hose guide.

5. Connect free end of hose to connections on machine or adjust hose stop so that desired length of hose extends from reel.

6. Connect flexible supply lines to swivel fitting. See HOSE INSTALLATION REFERENCE DRAWING.

NOTE: Do not hard plumb to swivel fitting.

7. Remove cover plate on spring housing to expose shaft and spring hub. (See Figure 1).

8. Insert spanner wrench into holes in spring hub (Fig 2). Rotate spanner wrench counter-clockwise. Number of 360˚ turns should match last digit in model number on serial plate.

WARNING

Some reels with large or multiple springs are equipped with a ratcheted adjustment wrench. Follow separate instruc- tions for its use. Failure to use ratcheted wrench, on reels so equipped, could result in serious personal injury.

MAINTENANCE

Periodically: A. Inspect hose

for wear and check mounting

bolts and other hardware for

tightness.

B. Check for broken springs

by pulling about 2/3 hose off

reel and observing “Broken

Spring Indicators” on sides of spring canisters (Fig. 3).

NOTE: Bearings and springs are prelubricated and require no periodic maintenance.

WARNING

Do not attempt to remove spring from its housing. Clock- type springs can be dangerous to handle. Removal of spring from housing could result in personal injury.

SPRING REPLACEMENT

The unique SAFETYCHANGE® spring motor consists of a spring and hub sealed within a housing. A replacement spring is supplied sealed in its housing and the old unit should be discarded completely.

1.

Turn off supply pressure to reel.

2. Insure that machinery to be serviced by reel is at

 

position closest to reel. Disconnect hose from

 

machine connections.

3.

Wind all hose onto reel to relieve all spring tension.

 

SPRING

 

HOUSING

 

COVER

 

PLATE

 

SPRING

Figure 1

HUB

 

COUNTER-

 

CLOCKWISE

 

FOR STANDARD

 

ROTATION

Figure 2

SPANNER

WRENCH

4.

Remove inspection cover from face of spring housing.

5.

Rotate spool clockwise and observe inner shaft.

 

Shaft should rotate clockwise and hub (with

 

spring attached) should remain stationary.

NOTE: Do not attempt to remove spring if resistance is met or hub tends to rotate with shaft. Continue to rotate spool and strike end of shaft several sharp blows with a lead hammer or rubber mallet until shaft rotates freely

and hub remains stationary.

CAUTION

Do not exceed number of turns indicated on serial plate. Over-tensioning can cause a broken spring, sheared shaft or other damage.

WARNING

Do not attempt to relieve spring tension using spanner

wrench. Doing so may result in personal injury.

6. Remove (4) bolts which secure spring motor to frame.

7. Slide spring motor off shaft and discard.

8. Install replacement spring motor, pawls and pawl springs.

NOTE: Pawl springs must be located between the pawls

and the deepest section of the shaft grooves.

Make sure that pawls and pawl springs are inserted flush

with ends of shaft and hub or they may rub against

inspection cover. See Fig 4, page 4.

CONTINUED ON BACK PAGE

Image 1
Contents Maintenance InstallationSpring Replacement UH24 Universal Hose REEL-DIRECT DriveReel Model Number Structure Accessory CodeDescription QTY UH 24 80 1 08 10 06 1 HSDSpool Lock DOG & RatchetRoller Hose Guides Hose Stops 340O Pivot BaseHose Installation Reference Drawing Hose InstallationHose Removal Gleason Reel Corp

UH24 specifications

The Hubbell UH24 is an innovative and versatile lighting solution designed for a range of settings, from industrial applications to commercial spaces. The fixture exemplifies Hubbell’s commitment to delivering high-performance lighting solutions that meet the needs of various environments while prioritizing energy efficiency and user comfort.

One of the standout features of the UH24 is its exceptional lumen output. With a powerful lighting capacity, the fixture provides ample illumination for large areas, making it ideal for warehouses, factories, and retail spaces. The UH24’s efficient LED technology ensures significant energy savings compared to traditional lighting options, which helps businesses reduce their overall energy costs and environmental footprint.

Another key characteristic of the UH24 is its robust construction. Built to withstand demanding conditions, the fixture is designed with durable materials that offer longevity and reliability. This rugged build quality means the UH24 is suitable for areas with high levels of activity or potential exposure to harsh elements, such as moisture or dust.

The UH24 also incorporates advanced thermal management technology, which promotes optimal performance and extends the lifespan of the fixture. By effectively dissipating heat, this technology minimizes the risk of overheating, ensuring consistent brightness and functionality even in high-temperature environments.

Flexibility is another hallmark of the Hubbell UH24. The fixture is available in various configurations and lumen packages, allowing for customization to meet specific project requirements. Whether it’s a high-bay installation in a warehouse or a low-bay setup in a retail environment, the UH24 can be adapted to suit diverse lighting needs.

Moreover, the UH24 supports a variety of control options, including dimming capabilities and occupancy sensors. This responsiveness not only enhances user comfort but also contributes to further energy savings by ensuring that lights are only on when needed.

In conclusion, the Hubbell UH24 is a top-of-the-line lighting fixture that combines high-performance capabilities with energy efficiency, durability, and flexibility. Its advanced technologies and features make it an exceptional choice for a variety of applications, ensuring that it meets the demands of modern lighting needs effectively. Whether in industrial or commercial settings, the UH24 stands out as a reliable and powerful lighting solution.