SCOREBOARD AC CABLE

WHITE - NEUTRAL (120VAC)

BLACK - LINE (120VAC)

GREEN - EARTH

2

PIN G

 

 

1

 

 

REVISION

DESCRIPTION

AUTH.

DATE

APVD

A

INITIAL DESIGN

 

05/20/03

 

D

4 POS. FEMALE CONNECTOR

NEUTRIK PART#

NC4FX

OES BIN#

CN137C

PIN 1 - V+ (DC CONTROLLER ONLY)

PIN 2 - COM (DC CONTROLLER ONLY)

PIN 4PIN 3 - WHITE (RS +)

PIN 1

PIN 2

PIN 3

PIN 4 - BLACK (RS -)

CABLING ROUTED

CTHROUGH GROUNDED METAL CONDUIT

SCOREBOARD DATA CABLE

WHITE - RS +

BLACK - RS-

RED - V+ (DC CONTROLLER ONLY)

BLACK - COM (DC CONTROLLER ONLY)

SHIELD - EARTH

SOLDER CUP VIEW

PIN G - NO CONNECTION

C

7 8 9

4 5 6

1 2 3

CLEAR 0 ENTER

CO 80537 • 970-667-1000 • Fax: 970-667-1032 • www.coloradotime.com

AC AND DATA CABLING MAY BE SEPARATED INTO INDIVIDUAL JUNCTION BOXES DEPENDING ON MODEL

B

SCOREBOARD WIRING:

RECOMMEND GROUNDED METAL CONDUIT FOR ALL WIRING. ->ELECTRICAL: 120VAC/230VAC, 60Hz, DEDICATED CIRCUIT

REFER TO MODEL SPECIFIC DOCUMENTATION FOR EXACT CURRENT LOAD

->CONTROLLER DATA: SHIELDED, 2 TWISTED PAIR, 24 GUAGE DATA WIRE ALL WIRING LOCATED WITHIN WEATHERPROOF ALUMINUM JUNCTION BOX LOCATED ON REAR OF SCOREBOARD.

SEEK THE SERVICE OF A QUALIFIED ELECTRICIAN TO ENSURE ALL

AWIRING MEETS APPLICABLE ELECTRICAL CODES.

4

3

ISC85X CONTROLLER

CONTROLLER WIRING:

B

 

CONNECT CONTROLLER DATA WIRE AS PER

PINOUTS DETAILED ABOVE.

DC CONTOLLER RECIEVES POWER FROM SCOREBOARD

AC AND RF CONTROLLERS WILL REQUIRE A 120VAC

RECEPTACLE NEAR CONTROLLER LOCATION.

NOTICE TO PERSON RECEIVING THIS DRAWING AND

OES, Inc.

 

 

 

 

TECHNICAL INFORMATION:

 

 

 

 

OES, INC. CLAIMS PROPERTY RIGHTS TO THE MATERIAL

4056 Blakie Road, London, ON N6L 1P7

 

 

 

DISCLOSED HEREIN. THIS DRAWING INCLUDES

Tel. (519) 652-5833

 

 

 

 

UNPUBLISHED PROPRIETARY MATERIAL DEVELOPED BY

 

 

 

A

OES, INC. AND AS SUCH IS NOT TO BE COPIED,

Fax. (519) 652-3795

 

 

 

REPRODUCED OR USED IN ANY WAY WITHOUT PRIOR

Email oes@oes-inc.com

 

 

 

WRITTEN AUTHORIZATION FROM OES, INC.

 

 

 

 

 

DESCRIPTION

 

 

 

 

 

 

OES ELECTRONIC SCOREBOARDS

 

APPROVED BY:

 

GENERIC OUTDOOR INSTALLATION

 

CHECKED BY:

SIZE

FILENAME

 

INIT DRAWING DATE

REV

THIRD ANGLE PROJECTIONS

B

800-INSTALL-001

 

05/20/2003

A

 

USAGE

 

 

 

 

 

 

 

 

 

 

 

INFORMATION ONLY

 

 

 

 

SCALE

N/A

DRAWN BY

JPG

PAGE

1 OF 1

2

 

 

1

 

 

 

INSTRUCTIONS

Image 6
Contents Page Instructions Indoor Scoreboards Instructions Instructions Generic Outdoor Installation Instructions Instructions Page Page Page Page Page Page ISC85X Intelligent Controller Basketball ISC85X Intelligent Controller