RESETTING YOUR PEDOMETER
Resetting TRIP Memories
Most people prefer to reset counts daily.To reset your regular counts (Trip Memories): From STEP,TIME, DISTANCE, or CALORIE mode, press and hold the yellow RESET button for at least 2 seconds.You’ll see the values all go back to zero. TheTOTAL memories stay as they are when resetting theTRIP memories.
Resetting TOTAL and TRIP Memories
To reset yourTOTAL Memories (which always resetsTRIP Memories) , go intoTotal Memory Recall Mode. Press and hold the yellow RESET button for at least 2 seconds to clear BOTH TOTAL and TRIP memories.
24
OTHER SETTINGS
The Step Filter and Unit of Measurement settings are accessed through a special “deep set” mode.
To enter this mode, press and hold the S1 (MEMORY) button for 4 seconds.The screen will display a single digit. From within Deep Set mode, press the S2 (MEMORY) button to cycle back and forth between the Step Filter set point and Choice of Unit System.
25
CHANGING STEP FILTER SETTING
While the JW200 PedometerEngine™ Step Sensor is extremely accurate, some people like to have the ability to filter out false steps. Therefore, the unit has a variable setting step filter, to allow
Press S3+ (MODE) or S3– (RESET) to change the Step Filter Setting.
26
Can be set |
|
| |
from | STEP | TIME DIST CAL | |
|
|
| |
steps |
|
|
|
“US” (English) or “EU” (Metric)
190 XLM | |
STEP TIME DIST CAL |
JW200 | S3- | S1,S2,S4 | S3+ |
|
Set Step Filter set point
190XLM
JW200 | S3- | S1,S2,S4 | S3+ |
|
|
| |||
Set measurement mode | 27 |
CHANGING UNITS (English vs. Metric)
The Pedometer can display either in English units (in, mi, and lb - this is the default), or in Metric units (cm, km, and kg). From within Deep Set mode (see pg. 25), press the S2 (MEMORY) button to cycle back and forth between setting the Step Filter set point and Choice of Unit System.The unit will show either “US” or “EU” (for European Union) depending on the unit system chosen. If you change units after using the pedometer, the unit will convert all of your data into the new unit system when you exit Deep Set model.You can check to see which system of units you are using by seeing which measurement units are displayed on the Stride and Weight setting screens.
Press S3+ (MODE) or S3– (RESET) to change the Measurement Mode. Press and hold S4 (MEMORY) for 2 seconds to exit Deep Set Mode.
Note:The unit will save any changes and exit set mode after 30
28seconds unattended.
REPLACING THE BATTERY AND MASTER RESET
When the display starts to dim or goes blank, it is time to replace the battery.
If the display is not uniformly dim or blank, and appears to display “erroneous data”, do a Master Reset by pressing all 3 buttons simultaneously for 3 seconds and then release.
The display should go blank, then turn all segments on, then display 0 steps in Step Mode.
Note: All the settings will return to their default setting values. If you need to change the battery, the settings will also revert to default settings.
29
To replace the battery:
1.Insert a coin into the slot on the bottom of the case, and twist to loosen the faceplate. Remove
faceplate and set aside.
2. Locate the battery holder as seen | Battery | |
on sketch. Pull out the old battery, | ||
| ||
and push a new |
| |
with positive terminal (+) facing up. |
|
3.Snap faceplate back into place, hooking the bottom two tabs first, then closing by pressing together at the top two tabs.
30
SPECIFICATIONS, FEATURES, and FUNCTIONS Description of Functions
•Counts Steps up to 99,999 then rollover.
•Has aTotal Memory for Steps that counts up to 99,999,999 steps, then rollover.
•CountsTime spent in step activity, up to 999 Min 59 sec, then rollover. Automatically counts whenever step activity is occurring.
•Has aTotal Memory for ActivityTime that counts up to 99,999 minutes, then rollover.
•Counts distance traveled during step activity, up to 999.99 mi or km, then rollover. Automatically counts whenever step activity is occurring.
31