How Desiccant Air Drying System Works

How Desiccant Air Drying System Works

AIR WET IN

AIR

DRY

OUT

Quick-remove flange

Built-in screen prevents desiccant from going down tube when refilled

288810 Blue silica gel desiccant beads turn pink when saturated.

After the moisture has been removed, the dry air passes through an element, up the center tube, and out the out- let port. As long as the desiccant is replaced at satura- tion point and your compressed air is not exposed to a temperature below the dew point, your equipment will receive dry, moisture-free air.

As the desiccant becomes saturated with moisture, the dew point begins to rise. This is evident when the desic- cant changes color from blue to pink, indicating the need for desiccant replacement. Refer to Desiccant Change- out, page 9.

Element prevents any desiccant dust from traveling downstream

Built-in sight glass allows easy monitoring of desiccant color change

When air is compressed, the temperature of the air increases, as does its capacity to hold moisture. As the hot, moist air travels down through the lines, it cools, allowing the moisture to condense. Filters, drain traps, and driplegs only remove liquid condensation. The Dryaire Desiccant Air Drying System removes liquid condensation, residual water vapor and aerosols.

As the wet compressed air flows through the inlet port and down the bed of desiccant, the desiccant beads absorb the water vapor and aerosols and can reduce the air humidity down to a -40°F (-40°C) pressure dew point.

2

309921N

Image 2
Contents Important Safety Instructions IncludesHow Desiccant Air Drying System Works Installation Shop Air Piping LayoutAir Hose Inside 10 ft 15 ft 20 ft 25 ft 50 ft Minimum Pipe Size RecommendationsCapacity Length 22 m 05 m 62 m 15.24 m .4 mm309921N Model 234401, Series D Coalescer Pressure Drop IndicatorOperation Model 24M178, Series BPart No. Description DescriptionAir Filter 234402, Series B Maintenance and RepairPressure Relief Procedure Coalescer 234397, Series BFollow the Pressure Relief Procedure, Desiccant Housing 234404, Series BDesiccant Housing Disassembly Desiccant ChangeoutSelf-Relieving Air Regulator CleaningAir Regulator Assembly For Desiccant Air Drying System 309921N Graco Standard Warranty Graco Phone Numbers