Whirlpool 8527809 installation instructions Three-wire connection

Page 10

Three-wire connection...

Three-wire receptacle

POWER SUPPLY CORD

spade terminals with upturned ends

ring terminals

This blade connected to this conductor.

NEUTRAL

3/4" U.L.-listed

NEUTRAL

 

strain relief

(white or center)

Three-wire power supply cord must have three, No.-10 copper wires and match a three-wire receptacle of NEMA Type 10-30R.

4.Loosen or remove center terminal block screw.

5.Connect the neutral wire (white or center) of power supply cord to the center, silver-colored terminal screw of the terminal block. Tighten screw.

6.Connect the other wires to outer terminal block screws. Tighten screws.

7.Tighten strain relief screws.

8.Reinstall terminal block cover to the dryer rear panel. Secure cover with hold-down screw.

DIRECT WIRE

Preparing the wire:

Three-wire with ground wire: Bare wire cut short. Wire is not used. Dryer is grounded through direct wire cable.

 

3/4" (1.9 cm)

1" (2.5 cm)

 

 

 

 

 

 

 

 

U.L.-listed strain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

relief

of wires

 

 

 

 

 

 

to

stripped of

 

 

 

 

 

 

insulation

 

 

 

 

 

 

disconnect

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEUTRAL wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10-gauge, 3-wire or,

 

 

 

10-gauge, 3-wire with

 

(white or center)

 

ground wire (Romex)

 

 

 

 

 

 

 

 

 

 

 

 

 

3-1/2" (8.9 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Strip 3-1/2" (8.9 cm) of

 

 

 

 

 

 

 

 

 

 

outer covering from

 

 

 

 

 

 

 

 

 

 

end of cable. Strip

 

 

 

 

 

 

 

 

 

 

insulation back

 

 

 

 

 

 

 

 

 

 

 

 

1" (2.5 cm). If using

 

 

 

Shape

 

 

3-wire cable with

 

 

 

 

 

 

 

 

 

 

 

 

ends of

 

 

ground wire, cut bare

 

 

 

 

 

 

 

 

wires into

 

 

wire even with outer

 

 

 

 

 

 

 

 

a hook.

 

 

covering.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Where local codes permit

connecting cabinet-ground conductor to neutral wire:

4. Loosen or remove center terminal block screw.

5. Place the hooked end of the neutral wire (white or center) of power supply cable under the center screw of the terminal block (hook facing right). Squeeze hooked end together. Tighten screw.

6. Place the hooked ends of the other power supply cable wires

under the outer terminal block screws (hook facing right). Squeeze hooked ends together. Tighten screws.

7. Tighten strain relief screws.

8. Reinstall terminal block cover to the dryer rear panel. Secure cover with hold-down screw.

Page 10

Image 10
Contents Installation Instructions Before you start It is your responsibility toImportant Setup Information Exhaust Hood TypeGas requirements Observe ALL Governing Codes and OrdinancesElectrical requirements Recommended ground methodNow Start Electrical requirements Direct wire U.S. only Power supply cordGrounding Instructions Four-wire connection Three-wire connection Direct Wire or Power Supply Cord Recessed area and closet installation instructions Product dimensions Bottom ExhaustInstructions d’installation Avant de commencer Votre sécurité et celle des autres est très importanteInformation Importante Pour LE Réglage Spécifications du système d’évacuationConservez CES Instructions Type DE Bouche DE DéchargeSécheuse à gaz SpécificationsInstallation électrique Méthode recommandée de liaison à la terreCommencer Risque du poids excessifSécheuse électrique Cablâge direct Cordon d’alimentationInstructions DE Liaison À LA Terre Circuit à quatre conducteurs… Cordon D’ALIMENTATIONCircuit à trois conducteurs… Cordon D’ALIMENTATIONSi les codes locaux ne permettent pas Déménagement de la Sécheuse Instructions d’entretienSi vous avez besoin ’aide Dimensions du produit Évacuation PAR LE BAS