Whirlpool GGW9260 Plan VentSystem, Typical exhaust installations, Optional exhaust installations

Page 10

Plan VentSystem

Typical exhaust installations

Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

 

B

 

C

 

D

A

E

 

F

 

G

 

H

A.Dryer

B.Elbow

C.Wall

D.Exhaust hood

E.Clamps

F. Rigid metal or flexible metal vent

G. Vent length necessary to connect elbows

H. Exhaust outlet

Optional exhaust installations

This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the dryer converted.

WARNING

Fire Hazard

Cover unused exhaust holes with one of the following kits:

279818 (white)

279925 (biscuit)

279969 (pewter)

Contact your local dealer.

Failure to follow these instructions can result in death, fire, electrical shock, or serious injury.

10

ABC

A. Standard rear offset exhaust installation B. Left or right side exhaust installation

C. Bottom exhaust installation (Not an option with pedestal installations.)

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.

AB

A. Over the top installation (also available with one offset elbow)

B. Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase. Please see the “Assistance or Service” section of this manual to order.

Over the top Installation: Part Number 4396028

Periscope Installation (For use with dryer vent to wall vent mismatch):

Part Number 4396037 - 0" (0 cm) to 18" (45.72 cm) mismatch

Part Number 4396011 - 18" (45.72 cm) to 29" (73.66 cm) mismatch

Part Number 4396014 - 29" (73.66 cm) to 50" (127 cm) mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

Image 10
Contents Electronic GAS Dryer Model GGW9260 8530063Table of Contents Dryer Safety Your safety and the safety of others are very importantImportant Safety Instructions ToolsandParts Installation InstructionsOptions LocationRequirements Installation clearancesDryer Dimensions You will need Recessed or closet installation Dryer on pedestal Minimum installation spacing for cabinet installation Mobile home Additional installation requirements Mobile home installations requireGas Type Gas SupplyRequirementsGas supply line Dryer gas pipe Gas supply pressure testingVentingRequirements Burner input requirementsAlternate installations for close clearances Typical exhaust installationsOptional exhaust installations Special provisions for mobile home installationsInstall VentSystem Determine Vent LengthMakeGasConnection Install LevelingLegsLevelDryer For mobile home useConnectVent CompleteInstallationIf the dryer will not start, check the following Starting YourDryer Dryer USETo use an Automatic Cycle ControlLocked PausingorRestartingStopping YourDryer LoadingDryingandCycleTips StatusLightsCycles AdditionalFeatures DryingRackEvery load cleaning CleaningtheDryerLocationCleaningtheLintScreen Dryer CareVacationandMovingCare CleaningtheDryerInteriorRemovingAccumulatedLint ChangingtheDrumLightTroubleshooting Assistance or Service Page Whirlpool Corporation will not pay for 8530063