Whirlpool 3978909 installation instructions Electrical Requirements, Gas supply Requirements

Page 3

Electrical

requirements

WARNING

Electrical Shock Hazard

Plug into a grounded 3-prong outlet. Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

Important: Observe all governing codes and ordinances.

A 120-volt, 60-Hz, AC-only, 15- or 20-ampere fused electrical supply is required. A time-delay fuse or circuit breaker is recommended.

It is recommended that a separate circuit serving only this appliance be provided.

A wiring diagram is located inside the console or on the inside of the lower front panel.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Recommended ground method

The dryer, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/NFPA 70*.

GROUNDING INSTRUCTIONS: This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

The power supply cord plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING - Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

3-prong ground-type outlet

3-prong ground plug

power

ground

supply cord

prong

Copies of the standards listed above may be obtained from:

*National Fire Protection Association Batterymarch Park

Quincy, Massachusetts 02269

Gas supply

requirements

WARNING

Explosion Hazard

Use a new AGA or CSA approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 13" water column. Examples of a qualified person include licensed heating personnel, authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

OBSERVE ALL GOVERNING CODES AND ORDINANCES.

Gas requirements:

Check that dryer is equipped with the correct burner for the particular type of gas in the home. Burner information will be found on the model/serial rating plate in door well of the dryer. If this information does not agree with the type of gas available, see your dealer.

power cord

gas pipe connection

Burner input requirements:

Elevations up to 10,000 feet:

The design of this dryer has been certified by CSA International for use at altitudes up to 10,000 feet above sea level at the B.T.U. rating indicated on the model/serial rating plate. Burner input adjustments are not required when the dryer is operated up to this elevation.

Elevations above 10,000 feet:

When installed above 10,000 feet, a four percent (4%) reduction of the burner B.T.U. rating shown on the model/serial rating plate is required for each 1,000 foot increase in elevation. For assistance installing dryer above 10,000 feet elevation, contact your serving gas supplier.

Supply line requirements:

shutoff valve “open” position

to dryer

rigid gas supply line

Provide a 1/2-inch IPS rigid gas supply line to the dryer location.

A combination of pipe fittings must be used to obtain an in-line connection to the dryer.

When acceptable to the gas supplier and local codes, 3/8-inch approved tubing may be used for lengths under 20 feet. For lengths over 20 feet, larger tubing should be used.

An individual manual shutoff valve must be installed within 6 feet of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1 – latest edition*.

Pipe-joint compounds resistant to the action of L.P. gas must be used.

red cap

If local codes permit, it is recommended that new flexible metal tubing, design-certified by AGA or CSA, be used for connecting the appliance to the rigid gas supply line. (The gas pipe which extends through the lower rear of the appliance has 3/8- inch male pipe thread.)

An elbow and connector between tubing and dryer pipe may be needed to prevent kinking.

A 1/8-inch NPT plugged tapping, accessible for test gauge connection, must be installed immediately upstream of the gas supply connection to the dryer.

The gas supply must have a shutoff valve. The valve should be within six feet of the dryer and in the same room. The location should be easy to reach for opening and closing the valve.

The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi.

Natural Gas:

This dryer is equipped for use with NATURAL GAS. It is design-certified by CSA International for L.P. (propane or butane) gases with appropriate conversion.

The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2psi.

L.P. Gas:

No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier.

Conversion must be done by a qualified service technician. Gas conversion kit part numbers are listed on the gas valve burner base.

Copies of the standards listed may be obtained from:

*CSA International

8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

Panel B

Image 3
Contents Instructions Your safety and the safety of others are very importantHave questions about your dryer? Moving dryer to a new location?Recessed area/closet installation Dryer location DimensionsProduct dimensions Exhaust dimensionsGas supply Requirements Electrical RequirementsPlan the exhaust vent installation Mobile home installation requirementsExhaust Requirements Level dryer Install vent SystemNew installation Prepare dryerFor more information, or to easily place your order, call To have your venting Professionally installed CallFor the nearest Authorized service Provider Exhaust dryerBefore you start VentingGas

3978909 specifications

The Whirlpool 3978909 is a highly acclaimed dryer heating element designed specifically for several models of Whirlpool dryers. This essential component plays a crucial role in drying clothes efficiently and effectively, ensuring users can enjoy optimal performance from their laundry appliances.

One of the main features of the Whirlpool 3978909 is its compatibility with a wide range of dryer models. This versatility makes it an ideal choice for homeowners looking to replace the heating element in older units or those experiencing heating issues in newer machines. The element is engineered to provide consistent heat output, which is pivotal for achieving the best drying results.

In terms of technology, the Whirlpool 3978909 utilizes high-quality materials designed to withstand high temperatures and extended use. This durability ensures that the heating element can last for many cycles without the need for frequent replacement. It is built to deliver efficient heating, reducing energy consumption while effectively drying clothes. The element heats up quickly, allowing for shorter drying times and improved appliance efficiency, which is a significant benefit for users looking to save time and energy costs.

The 3978909 model is also designed with user-friendliness in mind. Installation is straightforward, making it accessible even for those with limited DIY experience. The element typically comes with all necessary connectors and specifications for an easy replacement process, which can usually be done in under one hour.

Another characteristic that sets the Whirlpool 3978909 apart is its commitment to safety. The heating element is designed with various safety features to prevent overheating and other potential hazards, providing peace of mind for users. It operates quietly and efficiently, minimizing noise during operation while maximizing performance.

In summary, the Whirlpool 3978909 dryer heating element is a reliable and efficient component that enhances the drying capabilities of Whirlpool dryers. With its compatibility, durable design, user-friendly installation, and focus on safety, this heating element is an excellent investment for anyone looking to maintain their laundry appliances in peak condition. Whether replacing an old element or upgrading for better performance, the Whirlpool 3978909 stands out as a top choice among dryer heating solutions.