Frequently asked questions
Fault indicators
The "Check Filter/Vent" indicator lights.
Possible fault | Solution |
The dryer does not work at | – Usually cleaning the lint filter fixes the problem. |
its optimum or not efficiently. | If the problem persists, check all possibilities as |
The lint filter might be | described under "The program runs too long or |
clogged with lint or | stops". |
detergent residues. | – Open and close the door to turn off the |
| indicator. |
The exhaust duct may be too | With a long exhaust duct, program times and |
long. This is not a fault. | energy consumption increase. See Installation |
| Instructions. |
A program is canceled. |
|
The "Check Filter/Vent" indicator flashes.
The fault cannot be detected immediately.
–Check the possible faults as described above.
–Open and close the door to turn off the indicator.
–Start a program.
If the problem persists contact Technical Service.
The "Drying" indicator flashes.
The "Check Filter/Vent" and "Cooling down" indicators are lit. The drum rotates for approx. 2 minutes.
This is a technical fault.
Contact Technical Service.
The program is canceled.
The "Drying", "Rotary Iron", "Hand Iron", and "Normal" indicators flash. A new program start is not possible and the indicators will continue to flash.
This is a technical fault.
Contact Technical Service.
The dryer is making a thumping or grinding sound.
The sound is caused by the high airflow rate in the ducting of the dryer. This is not a fault.
–To determine if the noise is due to airflow, temporarily remove the exhaust duct from the machine. If the noise lessens, the ductwork is the cause of the noise. Rigid or flexible aluminum ducting is the best option for reducing the noise.
If the problem persists please contact Technical Service.