Frequently asked questions
What if the "Filter/Vent" fault indicator is lit?
Possible fault | Fix |
|
|
The lint filter is clogged. | Clean the lint filters. See "Dryer care". |
|
|
The air supply in the room is | Open a window or door to increase |
insufficient. | airflow. |
|
|
What if the program runs too long or stops?
Possible fault | Fix |
|
|
The airflow is insufficient in the area of | Open a window or door to increase |
the dryer. | airflow. |
|
|
The lint filters are clogged. | Clean the lint filters (see "Dryer care"). |
|
|
The laundry was not spun sufficiently in | Select a higher spin speed in the wash |
the washer. | program. |
|
|
The dryer is overloaded. | Reduce the load size. |
|
|
Metal zippers interfere with the dryer’s | Select a timed program to avoid |
moisture sensors. | overdrying. |
|
|
The condenser is clogged with lint or | Clean the condenser periodically (see |
detergent residue. | "Dryer care"). |
|
|
The air vent below the door is blocked. | Remove any blockages. |
|
|
What if the laundry is not dry enough?
Possible fault
The load contained too many dissimilar items (size and fabric.)
What if water has collected around the drum opening?
Possible fault
This is condensed moisture from the laundry.
21