Installation
Installation and Ventilation requirements
1 |
SUPPLY CORD |
AIR INLET |
VENTS |
HOT AIR |
OUTLET |
IMPORTANT: This dryer must be installed such that the air inlets and outlet are not restricted (fig. 1).
There should be a gap of at least 12mm (0.5 inches) between the sides and rear of the machine and the surrounding walls and cabinets.
To ensure adequate ventilation the space between the bottom of the machine and the floor must not be obstructed.
NEVER install the dryer up against curtains.
Prevent items from falling or collecting behind the dryer as these may obstruct the air inlet and outlet.
A venting hose is supplied with this tumble dryer.
Use the venting hose to exhaust hot air to the external atmosphere. This installation ensures the maximum drying efficiency and reduction of steam in the drying room.
2 |
WALL |
DRYER |
If the dryer is installed under a worktop or
The hose may be fitted through a wall or through an open door or window (fig.2). The hose is 95mm (3.75 inches) in diameter and will extend up to 1.8 metres (6 feet).
Venting hoses longer than 1.8 metres
(6 feet) are not recommended as the dryer performance will be reduced.
Ensure that the venting hose is not kinked as this will prevent the dryer from working efficiently.
4