Tricity Bendix W AW 1401 Electrical connection, Permanent connection, Blue- Neutral Brown- Live

Page 26

Electrical connection

Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.

WARNING: THIS APPLIANCE MUST BE EARTHED.

The manufacturer declines any liability should this safety measure not be observed.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance’s rating plate. The rating plate is located at the bottom of the rim of the open door.

 

Mod

 

Prod. No

P0042 BD

Ser. No

 

The appliance is supplied with a 13amp plug fitted. In the event of having to change the fuse in the plug supplied, a 13amp ASTA approved (BS 1363/A) fuse must be used.

Should the plug need to be replaced for any reason, proceed as described below.

The wires in the mains lead are coloured in accordance with the following code:

Green and Yellow

- Earth

Blue- Neutral

Brown- Live

GREEN & YELLOW

E

 

13 A

N

L

 

BROWN

BLUE

P1041

CORD CLAMP

 

The wire coloured green and yellow must be connected to the terminal marked with the letter «E» or by the earth symbol or coloured green and yellow.

The wire coloured blue must be connected to the terminal marked «N» or coloured black.

The wire coloured brown must be connected to the terminal marked «L» or coloured red.

Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.

WARNING:

A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard.

Ensure that the cut off plug is disposed of safely.

Should the appliance power supply cable need to be replaced, this must be carried out by our Service Force Centre.

Note

When the appliance is installed the power supply cable must be accessible.

Permanent connection

In the case of permanent connection it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current electrical regulations.

The switch must not break the yellow and green earth cable at any point.

26

Image 26
Contents AW 1201 W AW 1401 W Use InstallationChild Safety Contents Interest Environment Your New Washing MachineEcological hints Prewash Main wash Fabric softener Description of the ApplianceDetergent dispenser drawer Control Panel Programme information Programme progress displayProgramme selector dial Select the required programme Operating SequenceLoad the laundry Select Spin Reduction or no Spin optionAltering an option or a running programme Cancelling a programmeStart the programme Interrupting a programmeSelectSPIN Reduction or no Spin option Measure out the detergentMeasure out the fabric softener At the end Programme Washing Hints 1000g = 1 kgWhich detergent? Which form?Wash Care Symbols Important NotesOptions Load Time Mins Washing symbol Type of laundryWashing Programmes 60 50 Maintenance and Cleaning Cleaning the water inlet filter Emergency emptying outSomething Not Working Service & Spare Parts 0870 5European guarantee Guarantee ConditionsStandard guarantee conditions Customer Care DepartmentInstallation Instructions Technical SpecificationsUnpacking Installation on a Suspended FloorInstall the machine on a flat hard floor PositioningAppliance must be connected to a cold water supply Water inletWater drainage Into a drainage standpipeInterest of the environment LevellingSpecial conditions Onto a sink outlet spigotBlue- Neutral Brown- Live Electrical connectionPermanent connection Page Consumer care telephone number 08705 950