Tricity Bendix BIW 105 W Cleaning the water inlet filter, Emergency emptying out

Page 18

When no more water comes out, unscrew the pump cover and remove it. Always keep a cloth nearby to dry up spillage of water when removing the cover.

P1115

Remove any objects from the pump impeller by rotating it.

Put the cap back on the emergency emptying hose and place the latter back in its seat.

P1117

Screw the pump cover fully in.

Close the pump door.

Warning

When the appliance is in use and depending on the programme selected there can be hot water in the pump. Never remove the pump cover during a wash cycle, always wait until the appliance has finished the cycle, and is empty. When replacing the cover, ensure it is securely retightened so as to stop leaks and young children being able to remove it.

Cleaning the water inlet filter

If your water is very hard or contains traces of lime deposit, the water inlet filter may become clogged.

It is therefore a good idea to clean it from time to time.

Turn off the water tap. Unscrew the water inlet hose.

Clean the filter using a hard bristle brush.

Tighten up the inlet hose.

P1090

The dangers of freezing

If the machine is exposed to temperatures below 0°C, certain precautions should be taken.

Turn off the water tap.

Unscrew the inlet hose.

Place the end of the emergency emptying hose and that of the inlet hose in a bowl placed on the floor and let water drain out.

Screw the water inlet hose back on and reposition the emergency emptying hose after having put the cap on again.

When you intend to start the machine up again, make sure that the room temperature is above 0°C.

Important!

Every time you drain the water through the emergency emptying hose you must pour 2 litres of water into the main wash compartment of the detergent drawer and then run the drain programme. This will activate the ECO valve avoiding that part of the detergent remains unused at next washing.

Emergency emptying out

If the water is not discharged, proceed as follows to empty out the machine:

pull out the plug from the power socket;

close the water tap;

if necessary, wait until the water has cooled down;

open the pump door;

place a bowl on the floor and place the end of the emergency emptying hose into the bowl. Remove its cap. The water should drain by gravity into the bowl. When the bowl is full, put the cap back on the hose. Empty the bowl. Repeat the procedure until water stops flowing out;

clean the pump if necessary as previously described;

replace the emergency emptying hose in its seat after having plugged it;

screw the pump cover again and close the door.

18

Image 18
Contents BIW 105 W Installation Child SafetyUse Contents Your New Washing Machine Ecological hintsDescription of the Appliance Detergent dispenser drawerPrewash Main wash Fabric softener Control Panel Programme selector dial Programme informationLoad the laundry Operating SequenceSelect the required programme Select spin reduction or no spin optionAltering a programme Cancelling a programmeStart the programme Interrupting a programmeMeasure out the detergent Measure out the fabric softenerAt the end Programme Washing Hints 1000g = 1 kgWhich detergent? Which form?Wash Care Symbols Important NotesWashing symbol Type of laundry Dial position Washing ProgrammesLoad Washing symbol Type of laundry Options LoadMaintenance and Cleaning Cleaning the water inlet filter Emergency emptying outSomething Not Working Service & Spare Parts 0870 5European guarantee Guarantee ConditionsStandard guarantee conditions Customer CareInstallation Instructions Technical SpecificationsUnpacking Installation on a Suspended FloorInstall the machine on a flat hard floor PositioningAppliance must be connected to a cold water supply Water inletWater drainage Into a drainage standpipeOnto a sink outlet spigot LevellingSpecial conditions Entering the washing machinePermanent connection Interest of the environmentElectrical connection Blue- Neutral Brown- LivePage Consumer care telephone number 08705 950