Washer & Dryer Specifications
| Washers |
| Dryers | Stack Washer/Dryers | |||
| SWFT71, SWFY71 |
| Electric: SFET07, SFEY07 |
| Electric: STET77, STEY77 | ||
|
|
| |||||
|
|
| Gas: | SFGT09, SFGY09 |
| Gas: STGT79, STGY79 | |
2.84 (80) |
| 7.0 (198) |
| 2.84 (80)/7.0 (198) |
| ||
Width - in (mm) | 26 7/8" (683) |
| 26 7/8" (683) |
| 26 7/8" (683) |
| |
Depth - in (mm) | 28" (711) |
| 28" (711) |
| 28" (711) |
| |
Height* - in (mm) | 43" (1092) |
| 43" (1092) |
| 76 5/8" (1946) |
| |
Weight - lb (kg) | 250 (113) |
| Electric: 150 (68) |
| Electric: 360 (163) |
| |
|
|
| Gas: 155 (70) |
| Gas: 365 (166) |
| |
Shipping Weight - lb (kg) | 270 (123) |
| Electric: 160 (73) |
| Electric: 390 (177) | ||
|
|
| Gas: 165 (75) |
| Gas: 395 (179) | ||
Cycle Time - minutes | 27 |
| 45 |
|
| 27/45 |
|
Motor HP | 1 HP, 750 W |
| 1/3 HP, 5.5 amps |
| 1/3 HP, 5.5 amps | ||
|
|
|
|
|
| 1 HP, 750 W | |
Water Consumption - gal. per cycle | 14.8 |
| N/A |
|
| 14.8 |
|
Water Factor - gal. per cu. ft. | 5.2 |
| N/A |
|
| 5.2 |
|
Modified Energy Factor | 2.16 |
| N/A |
|
| 2.16 |
|
Hot Water Usage - gal. per cycle | 1.59 |
| N/A |
|
| 1.59 |
|
Water Pressure - psi (bar) | Pressure fill – 20 to 120 |
| N/A |
|
| Pressure fill – 20 to 120 |
|
| (1.4/8.3) |
|
|
|
| (1.4/8.3) |
|
Spin Speed - RPM | 500, 650, 1000 |
| N/A |
|
| 500, 650, 1000 |
|
Cycle/Temperature | Normal/Hot |
| High | 160º |
| See washer and dryer |
|
| Normal/Warm |
| Medium | 155º |
| columns for corresponding |
|
| Permanent Press/Warm |
| Low | 145º |
| cycles and temperatures. |
|
| Delicate/Cold |
| Delicate | 115º |
|
|
|
Electrical Specifications and |
| Electric: |
| See washer and dryer columns | |||
Circuit Requirements |
|
|
| for electrical specifications and | |||
|
|
| Gas: |
| circuit requirements. | ||
Motor - RPM | Inverter Drive |
| 60 Hz: 1725 |
| 60 Hz: 1725/Inverter Drive |
| |
Btu per Hour | N/A |
| 25,000 (6300 kcal) |
| 25,000 (6300 kcal) | ||
Heating Element** | N/A |
| 5350 W, 240 V |
| 5350 W, 240 V |
| |
|
|
| 4750 W, 208 V |
| 4750 W, 208 V |
| |
Type of Gas (Gas models only) | N/A |
|
| ||||
|
|
| mixed gas. Convertible |
| mixed gas. Convertible | ||
|
|
| to LP gas.*** |
| to LP gas.*** | ||
Utility Connections - in (mm) | N/A |
| Gas: 3/8" NPT (9.5) |
| Gas: 3/8" NPT (9.5) |
| |
Air Outlet Diameter - in (mm) | N/A |
| 4" (102) |
|
| 4" (102) |
|
Exhaust Airflow † - cfm (liters/sec.) | N/A |
| 220 (105) |
| 220 (105) |
| |
Maximum Exhaust | N/A |
| 0.6" W.C. |
| 0.6" W.C. | ||
Static Back Pressure |
|
|
|
|
|
|
|
Agency Approval | cULus |
| Electric: cULus |
| Electric: cULus |
| |
|
|
| Gas: CSA Star |
| Gas: CSA Star |
| |
Activation |
|
| |||||
No |
| No |
|
| No |
| |
Top Finish | Porcelain |
| Porcelain |
| N/A | ||
Colors | White |
| White |
|
| White |
|
Door Type | Window |
| Solid |
|
| Window |
*Heights may vary slightly depending on leveling adjustments.
**Factory equipped 120/240/60/1 - may be field converted to 120/208/60/1 by qualified servicer.
***IMPORTANT: Any product revisions or conversions must be made by the Manufacturer’s Authorized Dealers, Distributors, or local service personnel.
†Measured at point of exit from dryer.
At Speed Queen, we’re so confident that our
†† Parts only. Labor not included. See Speed Queen Warranty Bond for specifics.
For the most accurate information, the installation guide should be used for all design and construction purposes. Due to continuous product improvements, design and specifications subject to change without notice. The quality management system of Alliance Laundry Systems’ Ripon facility has been registered to ISO 9001:2000.
©Copyright 2010 Alliance Laundry Systems LLC
Printed in the U.S.A